Evidence map›Paper›PMID 42877457›Full record

ArticleJournal of contemporary brachytherapy2026

Dosimetric impact of computed tomography slice thickness-induced applicator reconstruction uncertainties in three-dimensional brachytherapy for cervical cancer.

Wei Huang, Haixia Cui, Dongshan Wei, Xiuquan Li, Qiong Wang, Qingfeng Jiang

Abstract read
In one paragraph

Article in Journal of contemporary brachytherapy, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Wei HuangDepartment of Oncology, Laboratory of Immunity, Inflammation & Cancer, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Haixia CuiDepartment of Oncology, Laboratory of Immunity, Inflammation & Cancer, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Dongshan WeiDepartment of Oncology, Laboratory of Immunity, Inflammation & Cancer, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Xiuquan LiDepartment of Oncology, Laboratory of Immunity, Inflammation & Cancer, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Qiong WangChongqing Engineering Research Center of Pharmaceutical Sciences, Chongqing Medical and Pharmaceutical College, Chongqing, China.
Qingfeng JiangDepartment of Oncology, Laboratory of Immunity, Inflammation & Cancer, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To evaluate the impact of computed tomography (CT) slice thickness on reconstruction accuracy of high-density tandem-ovoid applicators and resulting dose deviations in cervical cancer brachytherapy. Material and methods: Seventeen cervical cancer patients treated with CT-based brachytherapy using stainless steel tandem-ovoid applicators (2.50 mm slice thickness) were retrospectively analyzed. Homologous 0.625 mm, 1.25 mm, and 5.00 mm image sets were reconstructed from original CT raw data. Applicators were reconstructed on each thickness, and treatment plans from 2.50 mm images were copied to other sets. Applicator displacements, reconstruction uncertainties, and dose deviations at 1.25 mm, 2.50 mm, and 5.00 mm were compared with a 0.625 mm reference. Results: Slice thickness-induced partial volume effect caused applicator reconstruction uncertainties, predominantly in superior-inferior ovoid displacements, with maximum uncertainties approaching slice thickness. Each 1 mm superior-inferior displacement caused high-risk clinical target volume (HR-CTV) D Conclusions: CT slice thickness ≥ 2.50 mm introduces significant reconstruction inaccuracies, leading to clinically relevant dose deviations for HR-CTV and rectum. Reconstructing both 0.625 mm (for applicator reconstruction) and 2.50 mm (for contouring) images from a single scan is recommended for high-density applicator brachytherapy.

Indexed as

brachytherapycervical cancerCT slice thicknessdose deviationhigh-density applicatorsreconstruction uncertainties

Identifiers

PMID42877457
PMCPMC13662456

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.