ArticleClinics in orthopedic surgery2026

Increased Accuracy of Acetabular Cup Positioning with an Automatic Impaction Device in Total Hip Arthroplasty.

Hyeongmin Song, Chan Young Lee, Taek-Rim Yoon, Kyung-Soon Park

Abstract read
In one paragraph

Article in Clinics in orthopedic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Hyeongmin SongDepartment of Orthopedic Surgery, Chonnam National University Hwasun Hospital and Medical School, Hwasun, Korea.ORCID https://orcid.org/0000-0003-0817-3646
Chan Young LeeDepartment of Orthopedic Surgery, Chonnam National University Hwasun Hospital and Medical School, Hwasun, Korea.ORCID https://orcid.org/0000-0002-1394-0902
Taek-Rim YoonDepartment of Orthopedic Surgery, Chonnam National University Hwasun Hospital and Medical School, Hwasun, Korea.ORCID https://orcid.org/0000-0001-8282-1723
Kyung-Soon ParkDepartment of Orthopedic Surgery, Chonnam National University Hwasun Hospital and Medical School, Hwasun, Korea.ORCID https://orcid.org/0000-0002-5036-1803

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Traditionally, cementless total hip arthroplasty (THA) has been primarily performed using a manual technique involving a hammer and an impactor. During cup insertion into the acetabulum, the manual technique may cause temporary limitations in visualization, discrepancies in the applied force, and imbalances in the force vector. Recently, automatic impaction devices have been developed and adopted for cup insertion. The purpose of this study was to compare the accuracy of cup positioning in primary THA between the manual technique and the use of an automatic impaction device. Methods: A total of 67 hips that underwent primary THA were retrospectively evaluated: 36 hips using the manual technique and 31 hips using an automatic impaction device. The accuracy of acetabular cup positioning between the 2 groups was compared using the Lewinnek safe zone, which indicates accurate cup placement, based on postoperative measurements of cup anteversion and inclination angle. Six methods for measuring anteversion were applied in this study. In addition, the incidence of acetabular screw augmentation and the occurrence of intraoperative and postoperative complications up to 1 year after surgery were assessed. Results: The proportion of cases positioned within the Lewinnek safe zone was higher in the automatic group than in the manual group across all measurement methods. Regarding postoperative complications, 1 episode of dislocation occurred in the manual group, but the difference between the groups was not statistically significant. Conclusions: An automatic impaction device can improve the accuracy of THA cup positioning compared with the manual technique.

Indexed as

AcetabulumArthroplasty, Replacement, HipHip ProsthesisAgedFemaleHumansMaleMiddle AgedRetrospective StudiesAcetabular cupAutomatic impaction deviceTotal hip arthroplasty

Identifiers

PMID42877357
PMCPMC13662254

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.