Evidence map›Paper›PMID 42877106›Full record

ReviewOsteoporosis and sarcopenia2026

From underdiagnosis to scalable screening: Applications of artificial intelligence for vertebral compression fracture detection - a systematic review and meta-analysis of diagnostic performance.

Hsuan-Yu Chen, Linjun Yang, Gwen Wilson, Milos Brkljac, Monty S Khela, Kellen L Mulford, Cody C Wyles

Abstract readReview
In one paragraph

Review in Osteoporosis and sarcopenia, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hsuan-Yu ChenOrthopedic Surgery Artificial Intelligence Laboratory (OSAIL), Department of Orthopedics, Mayo Clinic, Rochester, MN, USA.
Linjun YangOrthopedic Surgery Artificial Intelligence Laboratory (OSAIL), Department of Orthopedics, Mayo Clinic, Rochester, MN, USA.
Gwen WilsonMayo Clinic Libraries, Mayo Clinic, Rochester, MN, USA.
Milos BrkljacOrthopedic Surgery Artificial Intelligence Laboratory (OSAIL), Department of Orthopedics, Mayo Clinic, Rochester, MN, USA.
Monty S KhelaOrthopedic Surgery Artificial Intelligence Laboratory (OSAIL), Department of Orthopedics, Mayo Clinic, Rochester, MN, USA.
Kellen L MulfordOrthopedic Surgery Artificial Intelligence Laboratory (OSAIL), Department of Orthopedics, Mayo Clinic, Rochester, MN, USA.
Cody C WylesOrthopedic Surgery Artificial Intelligence Laboratory (OSAIL), Department of Orthopedics, Mayo Clinic, Rochester, MN, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: Vertebral compression fractures (VCFs) are common and often missed on routine imaging. We systematically reviewed the diagnostic performance of artificial intelligence (AI) for VCF detection. Methods: A systematic review and meta-analysis were conducted following PRISMA 2020 and PROSPERO registration by searching Ovid Medline, Embase, and Central from January 1, 2020, to November 18, 2025, for studies using AI models for VCF detection and diagnosis. Risk of bias was assessed with QUADAS-2. Studies with complete 2 × 2 data were pooled using random-effects meta-analysis, with subgroup analyses by modality. Results: Fifty-one studies were included. Thirty-seven contributed to meta-analysis with around 259 190 participants and 45,346 VCF patients. Original radiology reports missed > 50% of incidental VCFs in many cohorts (up to 81%). The overall sensitivity of AI-assisted VCF detection was 85.0% (95% CI 84.2%-85.7%) and specificity 94.6% (95% CI 92.8%-95.9%). The positive and negative likelihood ratios were 15.4 and 0.16. At 22% pre-test probability, post-test probability was 77.7% after a positive AI result and 4.1% after a negative result. CT-based AI models performed best (sensitivity: 88.0%, specificity: 97.5%), while X-ray-based AI models showed lower sensitivity (79.2%) with high specificity (95.1%). Conclusions: AI models demonstrate high diagnostic accuracy for VCF detection, particularly in CT imaging. However, improved detection alone does not ensure better outcomes, as substantial treatment gaps persist. The clinical impact of AI depends on rigorous prospective external validation and integration into structured osteoporosis care pathways, linking automated identification to timely evaluation and secondary fracture prevention.

Indexed as

Artificial intelligenceDeep learningDiagnosisMeta-analysisVertebral compression fracture

Identifiers

PMID42877106
PMCPMC13662877

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.