Spatial robustness of P100 latency compared with amplitude: a data-driven rationale for visual pathway monitoring during neuroendovascular procedures.

Su Ji Lee, Sung-Chul Jin, Sung-Tae Kim, Hee-Eun Choi, Sang-Ku Park, Minjae Cho

Abstract read
In one paragraph

Article in Frontiers in neuroscience, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Su Ji LeeDepartment and Research Institute of Rehabilitation Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea.
Sung-Chul JinDepartment of Neurosurgery, Inje University Haeundae Paik Hospital, Busan, Republic of Korea.
Sung-Tae KimDepartment of Neurosurgery, Inje University Haeundae Paik Hospital, Busan, Republic of Korea.
Hee-Eun ChoiDepartment of Rehabilitation Medicine, Inje University Haeundae Paik Hospital, Busan, Republic of Korea.
Sang-Ku ParkDepartment of Neurosurgery, Konkuk University Medical Center, Seoul, Republic of Korea.
Minjae ChoDepartment of Neurosurgery, Seoul National University Bundang Hospital (SNUBH), Seongnam-si, Gyeonggi-do, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Intraoperative visual evoked potential (VEP) monitoring has a reputation for being unreliable, and much of that belongs to P100 amplitude. Amplitude shifts with electrode position, anesthetic depth, and dipole geometry. Practice has nonetheless tended to lean on amplitude, and to treat latency as the weaker of the two. Neuroendovascular procedures give reason to shift that emphasis. During open surgery there can be a mixture of direct and ischemic neural injury, whereas in an endovascular procedure the brain is not dissected and the monitored pathway is threatened almost exclusively through perfusion. Oligodendrocytes are more vulnerable to ischemia than neurons, so myelinated conduction may slow before neurons are lost, and latency may prolong before amplitude falls. We first asked whether latency can be measured reliably enough. In a retrospective series of 49 eyes from 28 patients, the median spatial variability index across O1, Oz, and O2 was 2.10% for P100 latency and 40.9% for amplitude. Amplitude varied more than latency in 47 of 49 eyes and in all 28 patients. Latency behaves as a stable temporal measure of signal arrival, amplitude as a spatially sampled field measure. Some evidence for this exists in intraprocedural somatosensory monitoring. In an exploratory analysis of successfully reperfused thrombectomy patients, tree-based models separated 90-day functional outcome more consistently and efficiently by latency than by amplitude. If VEP latency behaves the same way, monitoring need not depend on the parameter that is hardest to trust, and VEP could be used actively in these procedures. We therefore propose that reproducible P100 latency prolongation may mark evolving visual pathway ischemia, and specify three studies that would test it. The first measures the temporal variability of intraoperative P100 latency and reports the smallest change it can resolve. That number sets the floor for any alarm threshold, including one below the conventional 10%. The second follows retrochiasmal perfusion-risk procedures with concurrent electroretinography, asking whether latency prolongation tracks angiographic events and precedes major amplitude loss. The third separates retinal from central contributions in ophthalmic-territory procedures. The present data establish spatial robustness only. Temporal stability and ischemia detection are the endpoints of those studies.

Indexed as

intraoperative neurophysiological monitoringneuroendovascular proceduresP100 amplitudeP100 latencyspatial variabilityvisual evoked potential

Identifiers

PMID42877063
PMCPMC13662034

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.