Evidence map›Paper›PMID 42875705›Full record

ArticleAnnals of biomedical engineering2026

Pressure-Pressure Loop: A Novel Method for Biophysical Characterization of Blood Vessels.

Zehava Ovadia-Blechman, Moshe Halak, Dor Ben Ishay, Efrat Rushinek Cohen, Shay Maman, Moran Aviv, Neta Rabin

Abstract read
PubMed Publisher
In one paragraph

Article in Annals of biomedical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Zehava Ovadia-BlechmanSchool of Medical Engineering, Afeka Tel-Aviv Academic College of Engineering, Tel-Aviv, Israel. zehava@afeka.ac.il.ORCID http://orcid.org/0000-0002-7544-9705
Moshe HalakDepartment of Vascular Surgery, Sheba Medical Center, Tel Hashomer, Israel.
Dor Ben IshaySchool of Medical Engineering, Afeka Tel-Aviv Academic College of Engineering, Tel-Aviv, Israel.
Efrat Rushinek CohenSchool of Medical Engineering, Afeka Tel-Aviv Academic College of Engineering, Tel-Aviv, Israel.
Shay MamanSchool of Medical Engineering, Afeka Tel-Aviv Academic College of Engineering, Tel-Aviv, Israel.
Moran AvivSchool of Medical Engineering, Afeka Tel-Aviv Academic College of Engineering, Tel-Aviv, Israel.
Neta RabinSchool of Industrial and Intelligent Systems Engineering, Tel-Aviv University, Tel-Aviv, Israel.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo develop and evaluate a pressure-only method for localized functional characterization of synthetic vascular models and vascular grafts by capturing their integrated dynamic response and its interaction with stenosis severity.

methodsAn in-vitro closed-loop pulsatile flow system tested seven vascular models and grafts (silicone, latex, ePTFE, Dacron) at 0, 50, and 90% lumen narrowing. Two proximal high-fidelity pressure sensors recorded intraluminal pressure waveforms to construct pressure-pressure loops. Loop behavior was evaluated qualitatively through loop morphology and quantitatively using the slope descriptor (α). Uniaxial tensile testing provided independent Young's modulus measurements.

resultsIncreasing stenosis altered pressure magnitude while characteristic loop patterns remained recognizable across conditions, with severe stenosis modifying specific features without eliminating broader patterns. Silicone models showed broad loops, latex models displayed complex crossing patterns, and vascular grafts exhibited narrow, near-linear loops. Loop morphology and the repeatable slope descriptor (α) were consistent across measurements, together differentiating the integrated, configuration-specific dynamic responses of the tested vascular models and grafts.

conclusionPressure-pressure loop analysis provides a novel pressure-only framework for functional characterization of vascular models and grafts. Combining qualitative loop morphology with a reproducible quantitative slope descriptor, the approach captures complementary features of the integrated dynamic pressure response rather than a single intrinsic material property. The study demonstrates the feasibility of extracting meaningful descriptors from two intraluminal pressure waveforms in-vitro, supporting future validation in native blood vessels and applications in vascular graft design.

Indexed as

Biofluid mechanicsFunctional vascular characterizationPressure–pressure loopPressure waves analysisStenosisVascular grafts

Identifiers

PMID42875705

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.