Evidence map›Paper›PMID 42873453›Full record

ArticleJournal of clinical monitoring and computing2026

Clinical validation of an intra-abdominal pressure monitoring system by comparison with pneumoperitoneum pressure.

Franziska Günther, H Sijbrand Hofker, Ellen R Klinkert, Karin van der Tuuk, Maarten W Nijsten, Matijs van Meurs, Marije Smit

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of clinical monitoring and computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Franziska GüntherDepartment of Critical Care, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.ORCID http://orcid.org/0009-0000-8104-3181
H Sijbrand HofkerDepartment of Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
Ellen R KlinkertDepartment of Gynecology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
Karin van der TuukDepartment of Gynecology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
Maarten W NijstenDepartment of Critical Care, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.ORCID http://orcid.org/0000-0002-0981-9392
Matijs van MeursDepartment of Critical Care, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.ORCID http://orcid.org/0000-0002-7745-2772
Marije SmitDepartment of Critical Care, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands. m.smit@umcg.nl.ORCID http://orcid.org/0000-0002-4658-7287

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In critically ill patients, intra-abdominal hypertension (IAH) is associated with organ dysfunction and increased mortality. Acute kidney injury may occur early, since the kidney is particularly vulnerable to elevated intra-abdominal pressure (IAP). Accurate and timely measurement of IAP is essential for early detection of IAH and the initiation of appropriate therapeutic interventions. Therefore, the aim of this study was to assess the accuracy of an IAP monitoring system compared to a reference standard, the CO2 insufflator, during laparoscopy. The second aim was to assess the changes in renal biomarker levels during and after increases in IAP through pneumoperitoneum. A prospective cohort study in patients undergoing laparoscopy at the University Medical Center Groningen. IAP measurements were performed with a urinary catheter using an IAP monitoring system (Accuryn® Monitoring System, Accuryn Medical) and compared to the pressure set at the CO2-insufflator system. Bland-Altman analysis was performed with accounting for repeated measures. Urine samples were collected at several time-points and Kidney Injury Molecule 1 (KIM-1), Tissue Inhibitor of Metalloproteinase 2 (TIMP-2), urinary Neutrophil Gelatinase-Associated Lipocalin (NGAL), Liver-type Fatty Acid-Binding Protein (L-FABP), and albumin-creatinine ratio were measured. Between March 2025 and January 2026, 99 measurements were performed in 29 patients. One patient (3%) underwent hemicolectomy, and 28 patients underwent endometriosis surgery (97%). Analysis showed a bias of -1.4 mmHg (95% CI (-1.96 - (-0.82)) and limits of agreement of - 5.96 mmHg and 3.2 mmHg (95% CI -6.8-3.99) between the IAP monitoring system and the CO2-insufflators. The precision was 2.3 mmHg. The levels of renal biomarkers KIM-1, TIMP-2 and albumin/Cr ratio increased during laparoscopy compared to baseline, suggesting that relatively small IAP increases during laparoscopy have a subclinical effect on the kidney. The IAP monitoring system underestimated the IAP set by the CO2-insufflator by approximately 1 mmHg. The wide limits of agreement warrant cautious interpretation. Overall, the IAP monitoring system showed reasonable accuracy and precision. The increase of several renal biomarkers during laparoscopy compared to baseline may reflect a direct effect of elevated IAP on the kidney.

Indexed as

AccuracyBladder pressureIntra-abdominal pressurePneumoperitoneumPrecisionValidation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.