Impact of urine concentration and automatic interpretation on sensitivity and specificity of Legionella BinaxNOW
Article in European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeUrinary antigen tests (UATs) are widely used for rapid diagnosis of Legionnaires' disease (LD), primarily detecting Legionella pneumophila serogroup 1 lipopolysaccharide (LPS). Strategies, such as urine concentration, were shown to improve performance but mostly in retrospective studies.
methodsWe evaluated the impact of urine concentration on the diagnostic sensitivity and specificity of the BinaxNOW
resultsWe found that urine concentration significantly increased sensitivity by 9% before heat treatment. Automated interpretation increased sensitivity by 16.3% in unconcentrated samples. Before heat treatment, specificity remained high with visual interpretation (100% unconcentrated) but slightly decreased with automated reading (98% unconcentrated). After heat treatment, specificity reached 100% for all methods. In LPS-spiked samples, automated interpretation improved analytical sensitivity by 2- to 10-fold, particularly for mAb 3/1-positive strains.
conclusionBoth urine concentration and automated interpretation with the Digival™ reader increased the sensitivity of the BinaxNOW