Evidence map›Paper›PMID 42873055›Full record

ArticleNanomaterials (Basel, Switzerland)2026

PEDOT:PSS-Based OECT Common-Source Amplifiers for Electrophysiological Signal Amplification.

Kun Xu, Weiming Luo, Naichen Zhang, Yixin Cao, Xiaolei Li, Yujing Zhang, Yunqing Tang

Abstract read
In one paragraph

Article in Nanomaterials (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Kun XuCollege of Electrical Engineering, Henan University of Technology, Zhengzhou 450001, China.ORCID 0000-0003-3824-5153
Weiming LuoCollege of Electrical Engineering, Henan University of Technology, Zhengzhou 450001, China.
Naichen ZhangCollege of Electrical Engineering, Henan University of Technology, Zhengzhou 450001, China.
Yixin CaoCollege of Electrical Engineering, Henan University of Technology, Zhengzhou 450001, China.
Xiaolei LiCollege of Electrical Engineering, Henan University of Technology, Zhengzhou 450001, China.
Yujing ZhangCollege of Electrical Engineering, Henan University of Technology, Zhengzhou 450001, China.
Yunqing TangSchool of Mechanical Engineering, Shandong University, Jinan 250061, China.ORCID 0000-0003-1836-8674

Funding

Key Research and Development Program of Henan Province of China 251111221700National Natural Science Foundation of China 62303094Program for Science &Technology Innovation Talents in Universities of Henan Province 26HASTIT009Shandong Excellent Young Scientists Fund Program (Overseas) 2024HWYQ-003Young Taishan Scholars Program of Shandong Province tsqn202306087
6 · The paper itself

Abstract

Stable amplification of weak electrophysiological signals is important for low-voltage bioelectronic interfaces, but the gain and waveform fidelity of organic electrochemical transistor (OECT)-based amplifiers are strongly influenced by device characteristics and bias conditions. Herein, we develop a poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) vertical organic electrochemical transistor (vOECT) common-source amplifier using an integrated solid-state electrolyte and investigate its bias-dependent amplification behavior. The fabricated vOECTs exhibits typical p-type depletion-mode operation, effective gate-controlled current modulation, and a maximum transconductance of 22 mS. Transient measurements show reversible current switching with response time constants of 0.909 and 0.635 ms, while repeated gate-voltage modulation over approximately 1000 s confirms stable cycling behavior. Based on the measured transfer and output characteristics, a common-source amplifier model is constructed to analyze the relationship between gate bias, bias resistance, output swing, and voltage gain. By optimizing the voltage-divider bias network, the amplifier achieves a voltage gain of approximately 3.374. The optimized circuit amplifies sinusoidal signals from 1 to 100 Hz and simulated ECG, EEG, and EOG waveforms while preserving their main temporal features and producing the expected phase-inverted output. Distortion and frequency-response analyses further show a 1% total harmonic distortion point at an input peak amplitude of 113 mV and a -3 dB cut-off frequency of 625 Hz. These results demonstrate the importance of bias optimization for achieving stable low-frequency voltage amplification in PEDOT:PSS vOECT common-source amplifiers.

Indexed as

bias optimizationcommon-source amplifierelectrophysiological signal amplificationorganic electrochemical transistor

Identifiers

PMID42873055
PMCPMC13666998

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.