Long-term performance monitoring of a secondary electrospray ionisation high-resolution mass spectrometry platform using a vapor generator for routine quality control.
Article in Analytical methods : advancing methods and applications, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Secondary electrospray ionisation high-resolution mass spectrometry (SESI-HRMS) is a powerful, non-invasive tool for real-time breath analysis. However, instrumental drift, capillary degradation and other technical variations compromise clinical applications, especially for long-term studies, which require robust quality control (QC) methodologies. In this work, we present the use of an evaporation chamber-based reference gas system to monitor SESI-MS system performance over almost two years. Targeted QC measurements with deuterated butyric acid were recorded three times on each measurement day. Analytical stability was systematically quantified across both positive and negative ion modes. In a standalone continuous characterization, the reference gas generator delivered a stable signal over several hours. A Linear Mixed-Effects Model (LMM) was constructed to evaluate the influence of time-of-day on instrument performance. This revealed significant effects: positive mode signal intensity progressively increased throughout the day, whereas for negative mode, an initial drop in signal intensity and subsequent stabilisation was observed. Furthermore, the longitudinal QC framework successfully tracked capillary performance over time, providing objective performance metrics to retrospectively evaluate the impact of targeted hardware maintenance on system performance. The implementation of a structured QC protocol provides a valid methodology for long-term SESI-HRMS performance monitoring, ensuring data integrity and supporting the translation of SESI-HRMS into large-scale clinical applications.