Evidence map›Paper›PMID 42870657›Full record

ArticleJournal of applied clinical medical physics2026

Experimentally derived beam quality correction factors for PPC05 and razor nano ionization chambers in proton scanned beams based on graphite calorimetry.

Nicolás Gómez-Fernández, Séverine Rossomme, Eloy González-García, Lies Verpoest, Faustino Gómez, Alejandro Mazal, Juan Antonio Vera-Sánchez, Diego M González Castaño

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Nicolás Gómez-FernándezRadiation Physics Laboratory, AII, University of Santiago de Compostela, Santiago de Compostela, Spain.
Séverine RossommeClinical Department, Dosimetry, Ion Beam Applications, Louvain-la-Neuve, Belgium.
Eloy González-GarcíaRadiation Physics Laboratory, AII, University of Santiago de Compostela, Santiago de Compostela, Spain.
Lies VerpoestInstitut de Recherche Expérimentale et Clinique-Molecular Imaging Radiotherapy and Oncology (MIRO), UCLouvain, Louvain-la-Neuve, Belgium.
Faustino GómezRadiation Physics Laboratory, AII, University of Santiago de Compostela, Santiago de Compostela, Spain.
Alejandro MazalCentro Protonterapia, QuironSalud, Pozuelo de Alarcón, Spain.
Juan Antonio Vera-SánchezCentro Protonterapia, QuironSalud, Pozuelo de Alarcón, Spain.
Diego M González CastañoRadiation Physics Laboratory, AII, University of Santiago de Compostela, Santiago de Compostela, Spain.

Funding

Instituto de Salud Carlos III PI19/00263
6 · The paper itself

Abstract

backgroundIonization chamber based reference dosimetry of proton beam requires the use of beam quality correction factors which are obtained experimentally or by Monte Carlo simulation and are available to users in codes of practice and other publications. PURPOSE: The aim of this work is to determine experimental proton beam quality correction factors,

methodsMeasurements were performed in scanned clinical proton beams at two clinical centers. Absorbed dose to graphite was determined using a recently developed portable graphite calorimeter. The conversion factors for the absorbed dose to water determination were obtained by Monte Carlo simulations. Finally, the experimental

resultsFor the IBA PPC05 chamber, the experimental values agreed with recommended values tabulated in TRS-398 (rev. 1) within the combined experimental uncertainty for the three residual ranges of 3.4, 13.3 and 27.7 g·cm

conclusionsThis study demonstrates the feasibility and high precision of using a portable graphite calorimeter for beam quality correction factor determination in the user beam quality. The short room occupation time required (around 3 hours) makes the system useful as well for beam output dosimetry audits without disturbing clinical practice.

Indexed as

CalorimetryGraphiteMonte Carlo MethodPhantoms, ImagingProton TherapyRadiometryRadiotherapy Planning, Computer-AssistedHumansRadiotherapy DosageGraphitebeam quality correction factorscalorimetryProtontherapy reference dosimetry

Identifiers

PMID42870657
PMCPMC13662534

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.