Evidence map›Paper›PMID 42870074›Full record

ArticleOdontology2026

Effect of air-abrasion and air-polishing powders on dentin hydraulic conductance before and after acid challenge.

Elif Alkan, Eminenur Uytun, Buse Saraç, Hamit Enis Aslan, Ahmad Bittar, Bora Korkut, Dilek Tağtekin

Abstract read
PubMed Publisher
In one paragraph

Article in Odontology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Elif AlkanDepartment of Restorative Dentistry, Faculty of Dentistry, Marmara University, Marmara University Recep Tayyip Erdoğan Complex Health Campus, Başıbüyük Yolu 9/3, Başıbüyük/Maltepe, 34854, Istanbul, Turkey.ORCID http://orcid.org/0000-0001-7167-6946
Eminenur UytunDepartment of Restorative Dentistry, Faculty of Dentistry, Marmara University, Marmara University Recep Tayyip Erdoğan Complex Health Campus, Başıbüyük Yolu 9/3, Başıbüyük/Maltepe, 34854, Istanbul, Turkey.ORCID http://orcid.org/0009-0001-2193-3462
Buse SaraçDepartment of Restorative Dentistry, Faculty of Dentistry, Marmara University, Marmara University Recep Tayyip Erdoğan Complex Health Campus, Başıbüyük Yolu 9/3, Başıbüyük/Maltepe, 34854, Istanbul, Turkey.ORCID http://orcid.org/0009-0007-7311-1050
Hamit Enis AslanDepartment of Restorative Dentistry, Faculty of Dentistry, Marmara University, Marmara University Recep Tayyip Erdoğan Complex Health Campus, Başıbüyük Yolu 9/3, Başıbüyük/Maltepe, 34854, Istanbul, Turkey.ORCID http://orcid.org/0009-0002-4244-2758
Ahmad BittarDepartment of Restorative Dentistry, Faculty of Dentistry, İstinye University, No. 10, 215th Street, Ayazağa Neighborhood, Sarıyer, Istanbul, Turkey. ahmad.bittar@istinye.edu.tr.ORCID http://orcid.org/0009-0009-3305-5298
Bora KorkutDepartment of Restorative Dentistry, Faculty of Dentistry, Marmara University, Marmara University Recep Tayyip Erdoğan Complex Health Campus, Başıbüyük Yolu 9/3, Başıbüyük/Maltepe, 34854, Istanbul, Turkey.ORCID http://orcid.org/0000-0001-6360-9436
Dilek TağtekinDepartment of Restorative Dentistry, Faculty of Dentistry, Marmara University, Marmara University Recep Tayyip Erdoğan Complex Health Campus, Başıbüyük Yolu 9/3, Başıbüyük/Maltepe, 34854, Istanbul, Turkey.ORCID http://orcid.org/0000-0002-2675-1764

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Air-polishing and air-abrasion powders may contact exposed dentin, but their effects on fluid transport after acid exposure remain unclear. This in vitro study compared hydraulic conductance before and after powder application and acid challenge. Forty-two 1.0-mm coronal dentin discs were allocated (n = 7/group) to calcium sodium phosphosilicate bioactive glass (Sylc Powder), silica-coated aluminum oxide (CoSil Powder), sodium bicarbonate (AquaCare Sodium Bicarbonate), erythritol with 0.3% chlorhexidine (AIRFLOW PLUS Powder), sodium bicarbonate (AIRFLOW CLASSIC Powder), or untreated control. After 6% citric-acid conditioning for 10 min, baseline conductance was measured. Powders were applied for 15 s, and conductance was measured immediately. After 2% citric acid for 2 min, conductance was remeasured immediately. At 3 psi, 50-µL water transit was normalized to exposed area and pressure and expressed as µL·min⁻¹·cm⁻²·cmH₂O⁻¹. Data were analyzed by two-way mixed repeated-measures analysis of variance, stage-specific Tukey comparisons, and two-sided paired t tests with Holm adjustment. Stage (F(2, 72) = 117.95, p < 0.001) and the group-by-stage interaction (F(10, 72) = 11.77, p < 0.001) were significant. Conductance decreased from baseline in all five active groups (Holm-adjusted p ≤ 0.003) but not in the control (p = 0.681). After acid challenge, Sylc Powder remained lower than all other groups (p ≤ 0.014). Scanning electron microscopy provided illustrative morphology. Under this 15-s application and 2-min challenge protocol, responses depended on powder and stage; bioactive glass produced the most persistent reduction, whereas the other powders returned toward baseline.

Indexed as

Air abrasionAir polishingBioactive glassDentin hypersensitivityHydraulic conductance