Evidence map›Paper›PMID 42867775›Full record

ArticleRadiological physics and technology2026

End to end dosimetric and geometric verification of single isocenter multitarget stereotactic radiosurgery using an anthropomorphic phantom: external audit validation.

S Balasubramanian, D Anbalagan, P Thanasekar, Rashi Agrawal

Abstract read
PubMed Publisher
In one paragraph

Article in Radiological physics and technology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

S BalasubramanianDepartment of Radiation oncology, Max super speciality hospital Vaishali, W3, Sector 1, Vaishali, Ghaziabad, 201010, India. bals20@gmail.com.ORCID http://orcid.org/0000-0002-3057-4748
D AnbalaganDepartment of Radiation oncology, Max super speciality hospital Vaishali, W3, Sector 1, Vaishali, Ghaziabad, 201010, India.ORCID http://orcid.org/0000-0002-4695-899X
P ThanasekarDepartment of Radiation oncology, Max super speciality hospital Vaishali, W3, Sector 1, Vaishali, Ghaziabad, 201010, India.ORCID http://orcid.org/0000-0002-2042-0278
Rashi AgrawalDepartment of Radiation oncology, Max super speciality hospital Vaishali, W3, Sector 1, Vaishali, Ghaziabad, 201010, India.ORCID http://orcid.org/0000-0003-3150-9582

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Our study aimed to perform a comprehensive end-to-end (E2E) dosimetric and geometric evaluation of the newly commissioned Varian Edge linear accelerator (LINAC) with the HyperArc™ VMAT system for multi-target stereotactic radiosurgery (SRS) to ensure clinical accuracy and safety in the treatment of multiple brain metastases. E2E testing was conducted using the MAX-EA anthropomorphic phantom, incorporating ion chamber and film inserts. The phantom was immobilized with a Q-fix Encompass system and scanned with a 0.625 mm CT protocol. Five spherical PTVs range between (0.3-9.2 cc) were planned using Eclipse™ v18.01 with 6 MV-FFF beams and optimized via the Photon Optimizer algorithm with Acuros XB (1.25 mm grid). A HyperArc™ plan prescribing 15 Gy to each target was generated. Ionization chamber, Gafchromic EBT-XD film, portal dosimetry (EPID), and Multi-Target Winston-Lutz (W-L) tests were used to evaluate dosimetric and geometric accuracy. The measured-to-calculated dose difference was - 3.3% for the HyperArc plan. Film analysis yielded average gamma pass rates > 94.9% (2%/2 mm), > 96.5% (3%/1 mm) and > 98.68% (3%/2 mm). Portal dosimetry achieved > 96.05% average gamma pass (2%/2 mm). The W-L test all targets demonstrated localization accuracy within 0.5 mm and MPC measurements confirmed sub-millimeter isocenter accuracy within 0.29 mm. E2E evaluation of the Edge LINAC with HyperArc VMAT demonstrated submillimeter geometric precision and robust dosimetric accuracy. Also, the Results met AAPM-RSS benchmarks. While rigid phantom validation inherently idealizes real patient-specific anatomical and setup variations. These high-quality baseline results support the clinical accuracy of the treatment workflow.

Indexed as

Brain metastasesEnd-to-End (E2E) testingGafchromic filmHyperArcMAX-EA phantomSRSVarian edge LINACWinston-Lutz test

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.