Evidence map›Paper›PMID 42867024›Full record

Trial reportSkin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI)2026

Efficacy and Safety of 1.5- and 3.0-mm High-Intensity Focused Ultrasound for Eyebrow Lifting in Korean Adults: A Prospective Randomized Split-Face Study.

Kwang Ho Yoo, Hyewon Song, Yuhwa Choi

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Kwang Ho YooDepartment of Dermatology, Chung-Ang University Gwangmyeong Hospital, Chung-Ang University College of Medicine, Gwangmyeong-si, Gyeonggi-do, Republic of Korea.ORCID https://orcid.org/0000-0002-0137-6849
Hyewon SongClinical & Academic Affairs, Eunsung Global Co., Ltd., Wonju, Republic of Korea.
Yuhwa ChoiClinical & Academic Affairs, Eunsung Global Co., Ltd., Wonju, Republic of Korea.

Funding

Eunsung Global Co., Ltd.
6 · The paper itself

Abstract

backgroundHigh-intensity focused ultrasound (HIFU) is widely used for noninvasive eyebrow lifting, but within-subject comparisons of cartridge focal depths are scarce.

objectiveTo evaluate the efficacy and safety of 1.5- and 3.0-mm cartridges for eyebrow lifting in Korean adults, with an exploratory between-depth comparison.

methodsIn this randomized split-face study, 20 Korean adults were treated once with the 1.5-mm cartridge on one side and the 3.0-mm contralaterally (225 J/side). Average and maximum eyebrow heights (AEH, primary; MEH, secondary) were measured from standardized photographs at baseline, post-treatment, and weeks 1, 4, and 12. Satisfaction, pain, and adverse events were recorded.

resultsBoth measures increased significantly at all time points (unadjusted p < 0.05). At week 12, AEH increased by 1.76 ± 1.19 mm (1.5-mm) and 1.23 ± 1.33 mm (3.0-mm); 98.75% one-sided CI lower bounds (1.10 and 0.51 mm) met the corrected primary efficacy criterion. MEH met the separately corrected criterion with the 1.5-mm (0.57 mm) but not the 3.0-mm cartridge (-0.08 mm). The exploratory week-12 AEH difference was nonsignificant (p = 0.116). No treatment-related adverse events occurred over 12 weeks, supporting short-term tolerability in this cohort rather than definitive safety.

conclusionsEach cartridge was associated with significant within-subject increases in photographic eyebrow-height measures through 12 weeks and high satisfaction, although the corrected MEH criterion was not met with the 3.0-mm cartridge. Without a sham control, findings indicate within-subject improvement, not causal efficacy; the between-cartridge comparison is inconclusive, not evidence of equivalence. Larger, sham-controlled studies are needed.

Indexed as

EyebrowsRhytidoplastySkin AgingUltrasonic TherapyAdultFemaleHumansMaleMiddle AgedPatient SatisfactionProspective StudiesRepublic of KoreaTreatment Outcomeeyebrow liftingfocal depthhigh‐intensity focused ultrasoundKoreanskin tightening

Identifiers

PMID42867024
PMCPMC13659797

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked