A novel allograft combined with modified purse-string suture fixation for annulus fibrosus repair: biomechanical evaluation in a porcine lumbar disc model.

Yueh-Ying Hsieh, Lien-Chen Wu, Fon-Yih Tsuang, Che-Yung Kuan, Chang-Jung Chiang

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yueh-Ying HsiehDepartment of Orthopedics, Shuang Ho Hospital, Taipei Medical University, New Taipei, Taiwan.
Lien-Chen WuDepartment of Orthopedics, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan.
Fon-Yih TsuangDivision of Neurosurgery, Department of Surgery, National Taiwan University Hospital, Taipei, Taiwan.
Che-Yung KuanDepartment of Orthopedics, Shuang Ho Hospital, Taipei Medical University, New Taipei, Taiwan.
Chang-Jung ChiangDepartment of Orthopedics, Shuang Ho Hospital, Taipei Medical University, New Taipei, Taiwan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Annulus fibrosus (AF) defects may permit recurrent nucleus pulposus extrusion and are difficult to repair because of limited vascularity and persistent mechanical loading. Commercial bone-anchored annular closure devices are intended to occlude large post-discectomy defects, whereas tissue-derived grafts may provide an alternative defect-filling strategy. However, the immediate sealing performance of allograft-based AF repair remains incompletely characterized. Purpose: This study developed an allograft designed to stably repair AF defects and evaluated its sealing performance in porcine lumbar discs. Methods: Thirty porcine lumbar motion segments were allocated to five experimental groups. Group A received a 26-gauge annular puncture injury without repair and served as a puncture-reference condition rather than a defect-matched control. In Groups B1, B2, C1, and C2, a standardized 3-mm annular defect was created to accommodate a 3-mm-diameter allograft. Group B1 received a standard cylindrical allograft, whereas Group B2 received an allograft that expanded asymmetrically after hydration to form a truncated-conical geometry. Groups C1 and C2 received the corresponding allografts secured using modified purse-string suture (MPSS) fixation. Acute sealing performance was evaluated by static leakage testing, and primary statistical comparisons were restricted to Groups B1-C2. Results: Group A, included descriptively as a puncture-reference condition, had a mean failure pressure of 0.395 ± 0.083 MPa and was excluded from the primary inferential analysis. Among groups with standardized 3-mm defects, mean failure pressures were 0.802 ± 0.334 MPa for the standard cylindrical allograft (Group B1), 1.539 ± 0.334 MPa for the hydration-expanded truncated-conical allograft (Group B2), 2.638 ± 0.386 MPa for the standard cylindrical allograft with MPSS fixation (Group C1), and 2.892 ± 0.685 MPa for the hydration-expanded truncated-conical allograft with MPSS fixation (Group C2). Failure pressure differed significantly among Groups B1-C2 (p < 0.001). MPSS fixation significantly increased failure pressure for both graft configurations, whereas the difference between Groups B1 and B2 did not reach statistical significance after adjustment for multiple comparisons (adjusted p = 0.052). Conclusion: Among porcine lumbar motion segments with standardized 3-mm AF defects, MPSS fixation significantly increased acute leakage resistance for both graft configurations. The hydration-expanded truncated-conical allograft showed a higher mean failure pressure than the standard cylindrical allograft when used without fixation, although this difference did not reach statistical significance after adjustment for multiple comparisons. These findings support the acute mechanical feasibility of the allograft-MPSS construct.

Indexed as

annular repairbiomechanical evaluationherniated discsMPSS techniquetruncated-conical allograft

Identifiers

PMID42865908
PMCPMC13655539