Evidence map›Paper›PMID 42865805›Full record

ArticleJournal of thoracic disease2026

Procedural efficiency, diagnostic yield, and safety of a novel positioning grid combined with a non-coplanar puncture-angle guide for CT-guided percutaneous transthoracic lung biopsy: a retrospective contemporaneous-control study.

Ke Xu, Jiayi Chen, Sijia Deng, Aijun Jiang, Liantao Li

Abstract read
In one paragraph

Article in Journal of thoracic disease, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ke XuDepartment of Radiation Oncology, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, China.ORCID https://orcid.org/0009-0004-3771-6675
Jiayi ChenDepartment of Radiation Oncology, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, China.ORCID https://orcid.org/0009-0007-6998-5820
Sijia DengDepartment of Radiation Oncology, Chongqing University Fuling Hospital, Chongqing, China.ORCID https://orcid.org/0009-0000-5398-4726
Aijun JiangDepartment of Radiation Oncology, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, China.ORCID https://orcid.org/0000-0003-2230-1667
Liantao LiDepartment of Radiation Oncology, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, China.ORCID https://orcid.org/0000-0002-8788-2880

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Computed tomography (CT)-guided percutaneous transthoracic lung biopsy is an important method for obtaining pathological diagnoses of pulmonary lesions. However, conventional manual localization and needle advancement are operator dependent, and technically difficult lesions may require repeated angle adjustments and CT acquisitions. The aim of this study was to evaluate the procedural efficiency, diagnostic performance, and safety of a novel positioning grid combined with a non-coplanar puncture-angle guide. Methods: This single-center, retrospective, nonrandomized contemporaneous-control study included 287 patients who underwent CT-guided percutaneous transthoracic lung biopsy between August 2023 and November 2024. The device group comprised 146 patients treated using the novel positioning grid and angle guide, whereas 141 controls underwent biopsy using a conventional positioning grid without the angle guide. Procedure time, number of CT acquisitions, diagnostic yield, and complications were compared. Multivariable binary logistic regression was used to identify factors associated with pneumothorax. Results: Procedure time was shorter in the device group than in the control group (7.47±2.69 Conclusions: Use of the novel positioning grid combined with a non-coplanar puncture-angle guide was associated with shorter procedure time, fewer CT acquisitions, and lower rates of pneumothorax and hemoptysis while maintaining a high diagnostic yield. Prospective multi-operator studies are warranted because the present study was nonrandomized and the groups were treated by different operators.

Indexed as

Computed tomography-guided percutaneous transthoracic lung biopsy (CT-guided percutaneous transthoracic lung biopsy)diagnostic yieldpneumothoraxpositioning gridprocedural efficiencypuncture-angle guide

Identifiers

PMID42865805
PMCPMC13655806

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.