ArticleMedical & biological engineering & computing2026
RDB CycleGAN-CBAM: an integrated deep learning model for low-dose ct image denoising.
Article in Medical & biological engineering & computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Computed Tomography (CT) is one of the largest contributors to radiation exposure from medical imaging, which can induce DNA damage and increase cancer risk. Reducing CT radiation dose to improve patient safety inherently increases image noise and artifacts. Generative adversarial networks (GANs) have shown promise for unsupervised low-dose CT (LDCT) denoising. Building on this, RDBCycleGAN-CBAM, a CycleGAN-based model that integrates residual dense blocks (RDBs) and convolutional block attention modules (CBAM), was developed to effectively denoise quarter-dose CT images while preserving structural detail. The model was trained on unpaired quarter-dose and full-dose CT scans from the NIH-AAPM-Mayo dataset using adversarial (LSGAN), cycle-consistency, and identity losses. Evaluation on held-out test slices was performed using PSNR and SSIM as the primary image-quality metrics. The results demonstrate that the proposed RDBCycleGAN-CBAM method demonstrated improvements that were competitive with values reported in previous studies, achieving mean improvements of + 3.973 dB in PSNR and + 0.053 in SSIM relative to quarter-dose inputs. Shapiro-Wilk tests for PSNR and SSIM motivated the use of the nonparametric Wilcoxon signed-rank test, by which highly significant improvements across both metrics (PSNR and SSIM) were demonstrated. The very large rank-biserial correlation values (1.0) indicate that nearly all test images experienced substantial quality improvement. Furthermore, the narrow bootstrap confidence intervals for the mean differences suggest that these improvements are consistent across the dataset. These findings support further investigation of RDBCycleGAN-CBAM as a vendor-neutral image-domain denoising approach, while external validation and reader studies are required to establish its clinical utility and potential for dose reduction.
Indexed as
Identifiers
42862538What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.