Evaluation of a personalized total iodine dose (TID) combined with fixed injection duration (FID) protocol using high-concentration (400 mgI/mL) iodinated contrast medium in CT portal venography: a randomized trial.

Fanglu Zhou, Zhiwei Zhang, Hongwei Liang, Renqiang Yu, Wangjia Li, Xinyou Li

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Fanglu ZhouDepartment of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Zhiwei ZhangDepartment of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Hongwei LiangDepartment of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Renqiang YuDepartment of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Wangjia LiDepartment of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Xinyou LiDepartment of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The portal vasculature is closely associated with clinical outcomes in liver disease. Contrast-enhanced computed tomography (CT) serves as the first-line noninvasive tool for its evaluation. The contrast administration strategy critically influences CT image quality and diagnostic performance. This study aimed to investigate the effect of a personalized total iodine dose (TID) combined with a fixed injection duration (FID) protocol on CT imaging of the portal vein using a high-concentration iodine contrast medium (CM). Methods: A GE 64-slice spiral CT scanner and a 400 mgI/mL iodine CM were used. The total CM dose was calculated based on the patient's total body weight (TBW) at doses of either 400 or 450 mgI/kg. The FID was set at 18 or 20 s, and the tube voltage was set at 100 or 120 kVp. These three parameters were varied to generate eight distinct injection and scanning protocols. Eligible patients were randomized into eight groups. The CT values of the main portal vein (CT Results: Lower tube voltage significantly increased CT Conclusions: When using high-concentration iodine CM, all imaging protocols achieved satisfactory portal vein enhancement. The protocol combining a lower flow rate (20-s FID), a lower TID (400 mgI/kg), and a tube voltage of 100 kVp improved portal vein CT values and reduced radiation dose without compromising image quality, and thus represents a promising protocol for clinical CT portal venography.

Indexed as

image qualityIodine contrast medium (iodine CM)multi-slice spiral computed tomography (multi-slice spiral CT)portal vein imagingprotocol optimization

Identifiers

PMID42861095
PMCPMC13654128

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.