Evidence map›Paper›PMID 42860454›Full record

Observational studyJournal of robotic surgery2026

Femoral rotation and medial flexion gap tightness in functional alignment robotic total knee arthroplasty for varus knees.

Eduardo Frois Temponi, Pedro Henrique Oliveira Gomes, Alexandre Leite de Andrade, Miguel Jourdain Alípio do Vale, Matheus Braga Jacques Soares, Luiz Fernando Machado Soares, Lúcio Honório de Carvalho Júnior

Abstract readObservational Study
In one paragraph

Observational study in Journal of robotic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Eduardo Frois TemponiDepartment of Medicine, Pontifical Catholic University of Minas Gerais (PUC Minas), Belo Horizonte, Brazil. dufrois@gmail.com.
Pedro Henrique Oliveira GomesGrupo Joelho, Serviço de Ortopedia, Hospital Madre Teresa, Avenida Raja Gabaglia, Belo Horizonte, Minas Gerais, 1002, Brazil.
Alexandre Leite de AndradeGrupo Joelho, Serviço de Ortopedia, Hospital Madre Teresa, Avenida Raja Gabaglia, Belo Horizonte, Minas Gerais, 1002, Brazil.
Miguel Jourdain Alípio do ValeGrupo Joelho, Serviço de Ortopedia, Hospital Madre Teresa, Avenida Raja Gabaglia, Belo Horizonte, Minas Gerais, 1002, Brazil.
Matheus Braga Jacques SoaresGrupo Joelho, Serviço de Ortopedia, Hospital Madre Teresa, Avenida Raja Gabaglia, Belo Horizonte, Minas Gerais, 1002, Brazil.
Luiz Fernando Machado SoaresGrupo Joelho, Serviço de Ortopedia, Hospital Madre Teresa, Avenida Raja Gabaglia, Belo Horizonte, Minas Gerais, 1002, Brazil.
Lúcio Honório de Carvalho JúniorGrupo Joelho, Serviço de Ortopedia, Hospital Madre Teresa, Avenida Raja Gabaglia, Belo Horizonte, Minas Gerais, 1002, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Functional-alignment (FA) robotic total knee arthroplasty (TKA) combines component positioning and soft-tissue management. This study described the association between medial flexion-gap tightness and surgeon-selected femoral rotation, together with release grades and intraoperative gap asymmetry in varus knees. This observational single-surgeon study included the 65 varus knees in an 89-knee database. Medial tightness was defined as lateral minus medial preoperative flexion gap. Correlation and ordinary least-squares regression used 63 complete observations. Recorded preoperative, planned and final trial gaps were analysed with endpoint-specific denominators. An exploratory model considered tibial coronal positioning and posterior slope. Selected rotation was associated with medial tightness (Spearman ρ = 0.571; p < 0.001). The univariable fit was rotation = 1.93° + 0.343°/mm × tightness (R² = 0.257; slope 95% CI, 0.194-0.492). The adjusted slope was 0.296°/mm (95% CI, 0.131-0.460; n = 60). Release was mild in 64/65 and moderate in 1/65 knees. Mean absolute final asymmetry was 0.38 mm in extension and 0.29 mm in flexion. Asymmetry <1 mm occurred in 50/60 (83.3%) and 55/59 (93.2%), respectively; 53/58 (91.4%) met ≤1 mm in both positions. Greater medial flexion tightness was associated with greater selected femoral rotation. Predominantly mild release and small final mean asymmetry accompanied the combined workflow. The equation describes one surgeon's decisions and is not a validated surgical rule. These observations do not establish an independent release-sparing effect, clinical superiority of submillimetre symmetry, patellofemoral safety or long-term benefit.

Indexed as

Arthroplasty, Replacement, KneeFemurKnee JointOsteoarthritis, KneeRobotic Surgical ProceduresAgedFemaleHumansMaleMiddle AgedRange of Motion, ArticularRotationArthroplasty, Replacement, KneeArticularMedial collateral ligament, KneeOsteoarthritis, KneeRange of motionRobotic Surgical ProceduresRotation

Identifiers

PMID42860454
PMCPMC13654885

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.