Effect of Heat treatment parameters on the tribological performance of LM26/graphite/fly ash hybrid aluminium matrix composites using Taguchi-TOPSIS optimization.

Prakash Chellamuthu, Palanisamy Angappan, Palanisamy Duraisamy, Abhishek Agarwal, Karma Dorji

Abstract read
In one paragraph

Article in PloS one, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Prakash ChellamuthuDepartment of Mechanical Engineering, Roever Engineering College, Perambalur, TamilNadu, India.ORCID https://orcid.org/0000-0003-0393-9534
Palanisamy AngappanDepartment of Mechanical Engineering, Surya Engineering College, Erode, TamilNadu, India.
Palanisamy DuraisamyDepartment of Mechanical Engineering, Adhi College of Engineering & Technology, Kancheepuram, TamilNadu, India.
Abhishek AgarwalDepartment of Energy Technology, Tallinn University of Technology, Tallinn, Estonia.ORCID https://orcid.org/0000-0002-0900-6383
Karma DorjiDepartment of Mechanical Engineering, College of Science and Technology, Royal University of Bhutan, Phuentsholing, Bhutan.ORCID https://orcid.org/0009-0004-5006-865X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Hybrid aluminium matrix composites (HAMMCs) are of interest for lightweight components requiring improved resistance to wear and friction. The present study investigates the effects of solution treatment temperature, holding time and cooling method on the tribological behaviour of stir-cast LM26/graphite/fly ash hybrid aluminium matrix composites. A Taguchi L27 orthogonal array was used to evaluate solution treatment temperatures of 450, 500 and 550 °C, holding times of 2, 4 and 6 h, and furnace cooling, air cooling and water quenching. Hardness, wear rate and coefficient of friction (COF) were considered as response characteristics. TOPSIS was used for multi-response evaluation, and analysis of variance (ANOVA) was used to assess the contribution of the heat treatment parameters. Scanning electron microscopy (SEM) was used to examine reinforcement distribution in the matrix. The measured hardness ranged from 42.3 to 51.2 BHN, while the wear rate and COF ranged from 0.000667 to 0.000750 mm3/min and 0.4002 to 0.4501, respectively. The experimental results showed that hardness increased from 42.3 to 51.2 BHN, while wear rate and coefficient of friction decreased from 0.000750 to 0.000667 mm3/min and from 0.4501 to 0.4002, respectively, across the investigated conditions. Experiment 18, corresponding to 500 °C, 6 h and water quenching, gave the highest TOPSIS relative closeness value (0.8933). Factor-level analysis identified 550 °C, 6 h and water quenching (A3B3C3) as the optimum combination within the investigated design space. Temperature had the greatest influence on wear rate, coefficient of friction and the TOPSIS grade, whereas cooling method had the greatest influence on hardness. These results show that the selected heat treatment conditions substantially affected the combined hardness-wear-friction response of the hybrid composite under the investigated dry-sliding conditions.

Indexed as

AluminumCoal AshHot TemperatureFrictionHardnessMaterials TestingMicroscopy, Electron, ScanningAluminumCoal Ash

Identifiers

PMID42853823
PMCPMC13652234