Evidence map›Paper›PMID 42853434›Full record

ArticleClinical oral investigations2026

Comparison of additive and subtractive digital workflow for the accuracy of removable occlusal stabilization-splints - an in-vitro study.

Anna-Lena Willmann, Joachim Schroeder, Tudor Radu Popescu, Karin Jepsen, Søren Jepsen, Pia-Merete Jervøe-Storm

Abstract readComparative Study
In one paragraph

Article in Clinical oral investigations, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Anna-Lena WillmannDepartment of Operative Dentistry and Periodontology, University Hospital Bonn, Welschnonnenstrasse 17, 53111, Bonn, Germany.ORCID http://orcid.org/0009-0005-1882-474X
Joachim SchroederDepartment of Operative Dentistry and Periodontology, University Hospital Bonn, Welschnonnenstrasse 17, 53111, Bonn, Germany.
Tudor Radu PopescuPrivate Practice, Auf der Schleide 75, 53225, Bonn, Germany.
Karin JepsenDepartment of Operative Dentistry and Periodontology, University Hospital Bonn, Welschnonnenstrasse 17, 53111, Bonn, Germany.ORCID http://orcid.org/0000-0002-1015-3145
Søren JepsenDepartment of Operative Dentistry and Periodontology, University Hospital Bonn, Welschnonnenstrasse 17, 53111, Bonn, Germany.ORCID http://orcid.org/0000-0002-4160-5837
Pia-Merete Jervøe-StormDepartment of Operative Dentistry and Periodontology, University Hospital Bonn, Welschnonnenstrasse 17, 53111, Bonn, Germany. storm@uni-bonn.de.ORCID http://orcid.org/0000-0003-4697-6984

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesPatients with stage IV periodontitis often require additional rehabilitation of the compromised dentition due to anatomical and functional consequences of tooth loss. Removable occlusal splints can be helpful in these advanced cases. This in-vitro study compared the accuracy and internal fit of removable occlusal splints fabricated by 3D-printing and milling from a standardized STL-file. MATERIALS AND

methodsA standard-tessellation-language (STL)-file was created from a scanned master-model of the upper jaw and used for production of forty identical splints. Twenty splints were 3D-printed and twenty were milled. Subsequently all splints were rescanned, new STL-files resulted, which were compared with the original STL-file. Accuracy of both methods were assessed at 42 predefined points. Distances from vestibular to vestibular (v-v) respectively palatinal to palatinal (p-p) between molars were compared. Mann-Whitney-test was used for comparison (p < 0.05).

resultsMean values were 43.9 ± 31.29 μm (3D) and 22.0 ± 18.46 μm (milled), with a significant difference between groups (p < 0.001, Mann-Whitney). The 3D technique resulted generally in a contraction (mean (SD) v-v: mean - 13.0 μm (± 92.16); p-p: -9.3 μm (± 123.03)). With the milled technique, a contraction vestibular-to-vestibular (-4.0 μm (± 53.63)), but palatinal-to-palatinal an expansion was measured (38.5 μm (± 33.86)). Vestibular, differences between groups were not significant (p = 0.862, Mann-Whitney), but palatinal at the second molar (p < 0.001, Mann-Whitney).

conclusionBoth techniques showed deviations comparable to previous in-vitro studies of digitally manufactured occlusal splints. Less deviations were found in posterior areas of the dental arch with milled manufacturing. CLINICAL RELEVANCE: Manufacturing of removable occlusal splints with CAD/CAM appears to be a precise and comfortable option.

Indexed as

Computer-Aided DesignOcclusal SplintsPrinting, Three-DimensionalWorkflowHumansIn Vitro TechniquesModels, Dental3D-printedDigitalMilledOcclusal stabilization-splintPeriodontitisTooth mobility

Identifiers

PMID42853434
PMCPMC13652883

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.