Evidence map›Paper›PMID 42853285›Full record

ArticleJournal of artificial organs : the official journal of the Japanese Society for Artificial Organs2026

Axillary microaxial flow pump support for stepwise source control and bridge to durable left ventricular assist device therapy in cardiac device-related infective endocarditis.

Yohei Tamura, Shiro Nakahara, Masahito Saito, Kei Torikai, Koichi Toda, Isao Taguchi

Abstract readCase Reports
PubMed Publisher
In one paragraph

Article in Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yohei TamuraDepartment of Cardiology, Dokkyo Medical University Saitama Medical Center, 2-1-50 Minami Koshigaya, Koshigaya, Saitama, 343-8555, Japan.ORCID http://orcid.org/0009-0002-1532-4115
Shiro NakaharaDepartment of Cardiology, Dokkyo Medical University Saitama Medical Center, 2-1-50 Minami Koshigaya, Koshigaya, Saitama, 343-8555, Japan. nshiro@dokkyomed.ac.jp.
Masahito SaitoDepartment of Cardiovascular Surgery, Dokkyo Medical University Saitama Medical Center, Koshigaya, Japan.
Kei TorikaiDepartment of Cardiovascular Surgery, Dokkyo Medical University Saitama Medical Center, Koshigaya, Japan.
Koichi TodaDepartment of Cardiovascular Surgery, Dokkyo Medical University Saitama Medical Center, Koshigaya, Japan.
Isao TaguchiDepartment of Cardiology, Dokkyo Medical University Saitama Medical Center, 2-1-50 Minami Koshigaya, Koshigaya, Saitama, 343-8555, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cardiac device-related infective endocarditis complicated by end-stage heart failure poses a major therapeutic challenge because complete hardware removal is essential, whereas transvenous lead extraction may be poorly tolerated in patients with severe ventricular dysfunction and shock. We report a 53-year-old man with long-standing dilated cardiomyopathy and cardiac resynchronization therapy-defibrillator infection who presented with methicillin-sensitive Staphylococcus aureus bacteremia, pocket infection, respiratory failure, acute kidney injury, and a clinical presentation consistent with mixed septic-cardiogenic shock. Transthoracic echocardiography showed severe left ventricular dilatation and an ejection fraction of 10%. Because immediate extraction of a 17-year-old defibrillator lead was considered extremely high risk, an Impella 5.5 was implanted via the right subclavian artery, and surgical pocket drainage was performed as initial source control. After hemodynamic stabilization and reduction of vasoactive requirements, complete transvenous extraction of all leads was performed on hospital day 6 under ongoing Impella 5.5 support and cardiovascular surgical backup. During defibrillator lead traction, pulmonary artery pressure transiently decreased, but sustained systemic hemodynamic collapse did not occur. Following prolonged intravenous antibiotic therapy, blood cultures remained negative, renal function recovered sufficiently to discontinue continuous hemodiafiltration, and the patient was transferred to an advanced heart failure center. Durable left ventricular assist device implantation was subsequently performed successfully. This case suggests that axillary Impella 5.5 support may provide a stabilizing platform for staged source control, high-risk lead extraction, end-organ recovery, and bridge to durable mechanical circulatory support in carefully selected patients.

Indexed as

Defibrillators, ImplantableEndocarditis, BacterialHeart-Assist DevicesProsthesis-Related InfectionsStaphylococcal InfectionsBridge TherapyCardiomyopathy, DilatedDevice Lead ExtractionDevice RemovalHeart FailureHumansMaleMiddle AgedCardiac device-related infective endocarditisDilated cardiomyopathyImpella 5.5Left ventricular assist deviceMechanical circulatory supportTransvenous lead extraction

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.