ArticleBrazilian journal of cardiovascular surgery2026
K Pump-Mackenzie: Technological Development and Initial Bench Validation of a Fully Implantable 5G-Enabled Ventricular Assist Device.
Article in Brazilian journal of cardiovascular surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionAdvanced heart failure is an important cause of mortality in Brazil. Limited access to heart transplantation and the high cost of imported devices reinforce the need for national technological solutions. The K Pump-Mackenzie project proposes the development of a fully implantable mechanical circulatory assist device, integrated with 5G telemetry, with potential application in the unified health system of Brazil, the Sistema Único de Saúde.
methodsA centrifugal prototype rotor, with real-time control system and integrated flow and pressure sensors, was developed. The device was submitted to laboratory tests to evaluate mechanical performance, operational stability, structural integrity, and connectivity via 5G network. The preclinical protocol in the sheep model was designed and approved by the Comissão de Ética no Uso de Animais, from the Faculdade Evangélica Mackezie do Paraná, in accordance with Conselho Nacional de Segurança Alimentar e Nutricional guidelines.
resultsIn bench tests, the device showed controlled rotation of up to 10,000 rpm, adjustable flow between 2 and 6 L/min, and average latency of < 20 ms in data transmission. Continuous operational stability was observed for up to 72 hours, with adequate functioning of the monitoring and safety systems.
conclusionK Pump-Mackenzie demonstrated technical feasibility and satisfactory performance in initial bench validation. The planned preclinical stage will be fundamental to evaluate safety and biological performance, constituting a necessary step for future clinical application, and will take place in 2026.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.