Evidence map›Paper›PMID 42851273›Full record

ArticleFrontiers in cardiovascular medicine2026

Post-induction residual time: a novel sensing phenomenon during induced ventricular fibrillation in subcutaneous ICD recipients.

Carlos Lopez, Ignacio Mondragon, Mónica Benjamin, Leandro Tomas, Eliana Aversa, Mauricio Abello, Juan Armentano, Javier Chaves

Abstract read
In one paragraph

Article in Frontiers in cardiovascular medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Carlos LopezDivision of Cardiology, Hospital General de Agudos Dr. Cosme Argerich, Buenos Aires, Argentina.
Ignacio MondragonInstituto Cardiovascular de Buenos Aires, Buenos Aires, Argentina.
Mónica BenjaminHospital de Pediatria Prof Dr. Juan P. Garrahan, Buenos Aires, Argentina.
Leandro TomasSanatorio San Lucas-San Isidro, Buenos Aires, Argentina.
Eliana AversaHospital General de Agudos Juan A. Fernandez, Buenos Aires, Argentina.
Mauricio AbelloSanatorio Finochietto, Buenos Aires, Argentina.
Juan ArmentanoSanatorio Guemes, Buenos Aires, Argentina.
Javier ChavesClinica y Maternidad Colon, Mar del Plata, Argentina.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Subcutaneous implantable cardioverter defibrillators (S-ICD) are extensively used in the primary and secondary prevention of sudden cardiac death. Ventricular fibrillation (VF) induction during implantation remains standard to confirm device functionality. Objective: To compare electrocardiographic (ECG) and technical variables between induced and spontaneous ventricular arrhythmias in S-ICD recipients. Methods: A retrospective observational study was performed on 10 consecutive patients with S-ICD. Variables included episode duration, sensing time, charge time, and shock impedance. For each patient, the implant induced VF episode was compared to at least one spontaneous event during follow-up. Results: The mean age was 36.4 years (range: 22-61); 2 patients were male. All patients received intermuscular S-ICD implants, with the lead placed in the left parasternal position in 7 patients and right parasternal in 3. Episode duration and sensing time were consistently shorter in spontaneous events, and shock impedance was lower. Charge time, however, was longer in spontaneous events (by 1.4 to 1.8 s). Conclusions: In this case series, spontaneous ventricular arrhythmic events in S-ICD patients demonstrated shorter sensing and therapy delivery times compared with induced ventricular fibrillation episodes. A measurable Post-Induction Residual Time (PRT) was identified in all induced episodes and was absent during spontaneous ventricular arrhythmias, suggesting that 50-Hz-induced VF may not fully reproduce spontaneous arrhythmic events from the perspective of device sensing performance. These findings support the hypothesis that part of the delay observed during implant testing may be related to the induction process itself rather than to the intrinsic sensing capabilities of the S-ICD. Further studies are warranted to confirm these observations and to evaluate alternative VF induction strategies in future device platforms. Future integration of S-ICD systems with leadless pacing technologies may provide alternative ventricular fibrillation induction strategies, including T-wave shock delivery during either sensed intrinsic rhythm or leadless-paced rhythm. Such approaches could potentially avoid the occurrence of Post-Induction Residual Time (PRT) and may provide a model that more closely reproduces spontaneous ventricular fibrillation than current 50-Hz induction techniques.

Indexed as

ICD (implantable cardioverter-defibrillator)sensingS-ICDsudden cardiac deathventricular fibrillation

Identifiers

PMID42851273
PMCPMC13645546

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.