Phantom system for endotracheal tube cuff seal testing during mechanical ventilation.

Delu Zheng, Tamaralayefa B Agbiki, Ricardo Correia, Chenyang He, Sergiy Korposh, Sandor Erdody, Barrie R Hayes-Gill, David W Hewson, Andrew M Norris, Stephen P Morgan

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Delu ZhengOptics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK.
Tamaralayefa B AgbikiOptics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK.
Ricardo CorreiaOptics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK.
Chenyang HeOptics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK.
Sergiy KorposhOptics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK.
Sandor ErdodyOptics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK.
Barrie R Hayes-GillOptics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK.
David W HewsonAnaesthesia and Critical Care, Academic Unit of Injury, Recovery and Inflammation Sciences, School of Medicine, University of Nottingham, Nottingham, UK.
Andrew M NorrisMedical Photonics Limited, Nottingham, UK.
Stephen P MorganOptics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK. steve.morgan@nottingham.ac.uk.

Funding

MRC MR/Y008642/1
6 · The paper itself

Abstract

Leakage of orogastric secretions past endotracheal tube (ETT) cuffs contributes to ventilator-associated pneumonia (VAP), yet in vivo tracheal seal testing is impractical, requiring phantom evaluation. As the rigid cylinder specified in EN ISO 5361:2023 does not adequately represent in vivo airway conditions, a benchtop cuff seal testing system was developed incorporating a tracheal model, lung model, mechanical ventilation, and automatic cuff pressure control. A rigid cylinder and a bio-inspired tracheal model with tissue-like mechanical properties were evaluated using five high-volume low-pressure (HVLP) polyvinyl chloride (PVC) cuffed ETTs and five polyurethane (PU) cuffed ETTs, with and without mechanical ventilation, and with and without automatic cuff inflation. For PVC cuffed ETTs, fluid leakage rate was highest in the cylinder phantom compared with the bio-inspired phantom, ~ 30% lower without mechanical ventilation and ~ 50% with mechanical ventilation (both p < 0.001). In contrast, PU ETTs exhibited minimal leakage. Long-term testing revealed intracuff pressure decay over 48 h at 37 °C for both PVC (12.24 ± 1.13 cmH2O) and PU (9.06 ± 1.00 cmH2O) cuffed ETTs, while automatic cuff pressure control further reduced leakage for PVC ETTs. The bio-inspired phantom revealed sealing behaviours not captured by cylinder testing, supporting clinically relevant evaluation of ETT sealing performance and cuff materials.

Indexed as

Endotracheal tubeMechanical ventilationPhantomVentilator-associated pneumonia