ArticleJMIR formative research2026
Technical Feasibility of a Multimodal Electro-Optical and Infrared Imaging Pipeline for Postoperative Wound Assessment After Total Knee Arthroplasty: Formative Evaluation Study.
Article in JMIR formative research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundEarly detection and monitoring of wound-related complications after total knee arthroplasty (TKA) are critical to optimize outcomes and preserve implants. Conventional postoperative monitoring relies on in-person assessment and patient-reported symptoms, which may delay recognition. Noncontact imaging acquired in the clinic or at home offers a potential route to earlier and more consistent assessment.
objectiveThis study aimed to evaluate the technical feasibility and performance of a multimodal AI system integrating electro-optical (EO) and infrared imaging for postoperative wound assessment following TKA and to explore clinical factors associated with early complications.
methodsWe conducted a single-center prospective cohort study of 749 patients undergoing primary TKA. Patients underwent standardized multimodal data collection at scheduled postoperative visits. EO-based models localized surgical landmarks and segmented complication-oriented tissue states; a fine-tuned vision-language model provided protocol verification and contextual visual reasoning. EO landmarks mapped to thermal space via deterministic alignment, followed by infrared region-of-interest segmentation and thermal classification. Each module was evaluated on a defined held-out set. The thermal classifier was assessed out-of-fold under 5-fold cross-validation with folds grouped by patient, in knees imaged on postoperative day 14 or later. Discrimination for clinician-adjudicated infection-related complications served as the primary outcome. Comorbidities and baseline laboratory values were explored for associations with complications.
resultsAmong 749 patients, 26 (3.5%) had a clinician-adjudicated infection-related complication. On held-out evaluation, the EO landmark detector reached a sensitivity of 0.967 (95% CI 0.954-0.979) and positive predictive value of 0.955 (95% CI 0.940-0.970), and the wound-tissue segmentation model reached a sensitivity of 0.845 (95% CI 0.833-0.857) and positive predictive value of 0.759 (95% CI 0.744-0.772). Infrared region-of-interest extraction isolated the surgical field with a mean intersection-over-union of 0.985 (SD 0.008; 95% CI 0.984-0.986) across 178 held-out patients. The trained thermal classifier discriminated infected scans with an area under the receiver operating characteristic curve (AUROC) of 0.978 (95% CI 0.959-0.992) in out-of-fold, patient-grouped cross-validation. At a representative operating point, sensitivity was 0.808 (95% CI 0.65-0.92), specificity 0.974 (95% CI 0.96-0.99), positive predictive value 0.618 (95% CI 0.49-0.78), and negative predictive value 0.990 (95% CI 0.98-1.00). Exploratory analyses showed nominal associations of chronic kidney disease and diabetes mellitus with postoperative complications that did not remain significant after multiplicity correction.
conclusionsIn this formative study, a multimodal EO and infrared imaging pipeline demonstrated technical feasibility for postoperative wound assessment following TKA, providing noncontact discrimination of infection-related complications that compared favorably with established adjuncts. This work provides proof-of-concept for multimodal imaging-based assessment and defines the technical requirements for the prospective, multicenter external validation needed to establish clinical utility.
Indexed as
Identifiers
42849894What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.