Evidence map›Paper›PMID 42846946›Full record

ArticleFundamental research2026

Magnetic catheter robot with dynamic force feedback for stiffness identification and abnormality detection.

Haolan Shen, Zhengwei Li, Shixiong Fu, Mingguo Jiang, Mingxue Cai, Zhiqiang Chen, Hongwei Wang, Long Cheng, Tiantian Xu

Abstract read
In one paragraph

Article in Fundamental research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Haolan ShenGuangdong Provincial Key Laboratory of Robotics and Intelligent System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Zhengwei LiUniversity of Chinese Academy of Sciences, Beijing 100049, China.
Shixiong FuFuwai Yunnan Hospital, Chinese Academy of Medical Sciences, Affiliated Cardiovascular Hospital of Kunming Medical University, Kunming 650000, China.
Mingguo JiangGuangdong Provincial Key Laboratory of Robotics and Intelligent System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Mingxue CaiGuangdong Provincial Key Laboratory of Robotics and Intelligent System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Zhiqiang ChenGuangdong Provincial Key Laboratory of Robotics and Intelligent System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Hongwei WangGuangdong Provincial Key Laboratory of Robotics and Intelligent System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Long ChengUniversity of Chinese Academy of Sciences, Beijing 100049, China.
Tiantian XuGuangdong Provincial Key Laboratory of Robotics and Intelligent System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Magnetic continuum robots offer unique advantages for minimally invasive surgery owing to their flexibility, miniaturization, and remote actuation. However, the absence of reliable real-time force feedback in existing magnetically actuated catheters severely constrains safe interaction, and quantitative identification of tissue mechanical properties. To address this limitation, this work presents a magnetic catheter robot with integrated dynamic force feedback. The proposed system integrates an axial optical force sensor, a miniaturized endoscope, and annular permanent magnets within a compact distal architecture. This design achieves sub-0.01 N force resolution while remaining robust under large bending deformations and varying deflection angles. System performance is quantitatively evaluated through force-controlled planar writing, 3D curved-surface palpation with shape perception and stiffness mapping, and endoscope-guided bronchial palpation, demonstrating reliable stiffness-based abnormality detection in complex luminal environments. These results demonstrate the feasibility of force-aware magnetic catheterization for quantitative assessment of local tissue mechanics, providing a clinically relevant platform for minimally invasive diagnostics.

Indexed as

Abnormality detectionDynamic force feedbackMagnetically actuated catheterMinimally invasive surgeryQuantitative stiffness identification

Identifiers

PMID42846946
PMCPMC13644473

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.