Influence of constraint mechanism on kinematics, contact mechanics, and polyethylene wear in dual-axis rotating hinge and ball-and-socket knee prostheses: a finite element study.

Jinwei Liu, Xiaoyi Wang, Chuanhao Guo, Yongcheng Hu, Weiguo Xu, Jingyu Zhang

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jinwei Liu *Department of Bone Tumor and Soft Tissue Oncology, Tianjin Hospital, Tianjin University, Tianjin, China.
Xiaoyi Wang *Department of Bone Tumor and Soft Tissue Oncology, Tianjin Hospital, Tianjin University, Tianjin, China.
Chuanhao GuoClinical School, College of Orthopaedics, Tianjin Medical University, Tianjin, China.
Yongcheng HuDepartment of Bone Tumor and Soft Tissue Oncology, Tianjin Hospital, Tianjin University, Tianjin, China.
Weiguo XuDepartment of Bone Tumor and Soft Tissue Oncology, Tianjin Hospital, Tianjin University, Tianjin, China.
Jingyu ZhangDepartment of Bone Tumor and Soft Tissue Oncology, Tianjin Hospital, Tianjin University, Tianjin, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Severe metaphyseal bone defects following revision total knee arthroplasty or tumor resection often require highly constrained knee prostheses. Although rotating hinge knee (RHK) designs provide reliable stability, polyethylene wear and aseptic loosening remain important concerns. A novel ball-and-socket knee prosthesis has been developed to improve rotational accommodation and joint kinematics; however, its biomechanical performance relative to conventional rotating hinge designs remains unclear. Methods: Finite element models of a dual-axis rotating hinge knee prosthesis and a ball-and-socket knee prosthesis were developed and subjected to five million gait cycles under ISO 14243-1:2009 loading and motion conditions. Kinematics, contact mechanics, and polyethylene wear were evaluated using a contact-pressure-independent modified Archard wear formulation incorporating cross-shear effects. The reported wear volume for the ball-and-socket prosthesis represents the analyzed bearing side and its associated constraint interfaces. Results: Both prosthetic designs exhibited limited anterior-posterior translation and maintained relatively low contact pressures due to highly conforming articulations. Compared with the dual-axis rotating hinge prosthesis, the ball-and-socket prosthesis demonstrated greater internal-external rotational freedom (21.6° vs. 3.2°) and broader contact migration during gait. Although the ball-and-socket design exhibited larger contact areas and lower contact pressures, its polyethylene wear rate (10.06 mm Conclusion: Prosthetic design influences kinematics, contact mechanics, and wear behavior in highly constrained knee systems. The results indicate that multidirectional motion and cross-shear may play a more important role in polyethylene wear than contact pressure alone. Although the ball-and-socket prosthesis exhibited greater wear than the dual-axis design, it provided increased rotational accommodation and may better accommodate rotational demands during gait. These features support its potential as an alternative design strategy for constrained knee reconstruction after further experimental validation and design optimization. Future optimization should focus on reducing excessive multidirectional sliding and cross-shear while preserving rotational adaptability.

Indexed as

finite element modelkinematicsprosthesis designrotating hinge kneewear simulation

Identifiers

PMID42846074
PMCPMC13642287

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.