Evidence map›Paper›PMID 42845881›Full record

ArticleFrontiers in pharmacology2026

Changes in device-matched peak inspiratory flow after bedside inhaler coaching and factors associated with residual suboptimal flow: a retrospective observational study.

Yuhang Ding, Pengnan Xu, Yanhong Meng, Jinping Zhang, Qiuhui Wu

Abstract read
In one paragraph

Article in Frontiers in pharmacology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yuhang DingDepartment of Pharmacy, Nanjing Drum Tower Hospital, China Pharmaceutical University, Nanjing, China.
Pengnan XuDepartment of Pharmacy, Nanjing Drum Tower Hospital, China Pharmaceutical University, Nanjing, China.
Yanhong MengDepartment of Pharmacy, Nanjing Drum Tower Hospital, China Pharmaceutical University, Nanjing, China.
Jinping ZhangDepartment of Pharmacy, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China.
Qiuhui WuDepartment of Pharmacy, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Peak inspiratory flow rate (PIFR) is a critical determinant of inhaler-device compatibility, particularly when assessed under resistance conditions matching the prescribed inhaler. However, changes in device-matched PIFR patterns after inhaler coaching and factors associated with persistent abnormalities remain insufficiently characterized among hospitalized patients with chronic airway diseases. Methods: We conducted a retrospective single-center observational study of hospitalized adults with chronic obstructive pulmonary disease, asthma, or asthma-COPD overlap who underwent routine device-matched PIFR assessment between July 2024 and December 2025. PIFR was measured using the In-Check DIAL G16 before and after standardized bedside coaching under resistance settings matched to the prescribed inhaler. Logistic regression analyses were performed to identify factors associated with persistent post-coaching PIFR abnormalities. Results: Among 286 patients, the distribution of device-matched PIFR shifted substantially toward the device-specific optimal PIFR range after bedside assessment and coaching. The proportion of patients within the optimal PIFR range increased from 42.3% to 89.2%, whereas insufficient and excessive PIFR decreased from 25.2% to 6.9% and from 32.5% to 3.9%, respectively (all P < 0.001). Lower body mass index was independently associated with persistent insufficient PIFR, whereas ICS-containing therapy was also associated with this residual abnormality. Persistent excessive PIFR was uncommon and primarily observed among patients using pMDI/SMI devices. Conclusion: Device-matched PIFR assessment combined with individualized coaching was associated with a substantial shift toward the device-specific optimal PIFR range among hospitalized patients with chronic airway diseases. However, persistent insufficient PIFR remained in a subset of patients and was associated with lower BMI and ICS-containing therapy, suggesting that these factors may help identify patients who warrant closer reassessment of inhaler-device compatibility.

Indexed as

chronic airway diseasedevice resistancehospitalized patientsinhaler devicespeak inspiratory flow training

Identifiers

PMID42845881
PMCPMC13642123

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.