Evidence map›Paper›PMID 42841981›Full record

ArticleUrolithiasis2026

Slippery when wet: The effect of a novel zwitterionic coating on silicone ureteral stents.

Ye Jean Lim, Ye Na Diana Lim, Connor A Church, Elijah Haynal, Elizabeth A Baldwin, D Duane Baldwin

Abstract read
In one paragraph

Article in Urolithiasis, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ye Jean LimDepartment of Urology, Loma Linda University Health, 11234 Anderson Street, Loma Linda, CA, 92354, USA.
Ye Na Diana LimDepartment of Urology, Loma Linda University Health, 11234 Anderson Street, Loma Linda, CA, 92354, USA.
Connor A ChurchDepartment of Urology, Loma Linda University Health, 11234 Anderson Street, Loma Linda, CA, 92354, USA.
Elijah HaynalDepartment of Urology, Loma Linda University Health, 11234 Anderson Street, Loma Linda, CA, 92354, USA.
Elizabeth A BaldwinDepartment of Urology, Loma Linda University Health, 11234 Anderson Street, Loma Linda, CA, 92354, USA.
D Duane BaldwinDepartment of Urology, Loma Linda University Health, 11234 Anderson Street, Loma Linda, CA, 92354, USA. dbaldwin@llu.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Silicone ureteral stents provide anti-encrustation properties and patient comfort but are more difficult to insert and remove due to increased surface friction. Applying zwitterionic coatings to silicone stents may reduce friction and facilitate stent placement and removal. This study compared the frictional forces of zwitterionic-coated silicone stents with commercial stents using benchtop models. The static and kinetic frictional forces of five ureteral stents were measured: bare silicone stent without coating (BS), single outer-coated zwitterionic silicone stent (Z1), double-coated (inner and outer) zwitterionic silicone stent (Z2), Black Silicone Filiform stent ("Black Beauty") (BB), and Universa Soft stent (US). Friction was assessed with a submerged guidewire model to isolate stent-guidewire friction and a porcine ureteral model to simulate intraoperative stent insertion and removal. Five trials per stent were performed using a force gauge integrated with an Arduino-controlled motor system. Statistical significance was assessed using linear mixed-effects models with stent type and trial as fixed effects and ureter specimen as a random intercept. Pairwise comparisons were adjusted using the Holm method. In the submerged guidewire model, Z2 had 99%, 47%, and 40% lower kinetic friction than BS, BB, and US, respectively. During stent insertion, Z2 had 71%, 43%, and 44% lower kinetic friction than BS, BB, and US, respectively. During stent removal, Z2 had 92%, 58%, and 60% lower kinetic friction than BS, BB, and US, respectively. Linear mixed-effects models demonstrated a significant effect of stent type for all six friction conditions (all p < 0.001). The double-coated (inner and outer) zwitterionic silicone stent (Z2) demonstrated the lowest frictional forces across all testing conditions. Zwitterionic surface modification may therefore reduce friction during silicone stent placement and removal.

Indexed as

Coated Materials, BiocompatibleSiliconesStentsUreterAnimalsFrictionMaterials TestingProsthesis DesignSwineCoated Materials, BiocompatibleSiliconesFrictionLubricantsSiliconeStentsUreter

Identifiers

PMID42841981
PMCPMC13645972

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.