Evidence map›Paper›PMID 42840586›Full record

ArticleEuropean heart journal. Imaging methods and practice2026

A framework for increasing scanner efficiency: the utility of a 'Short aorta' protocol to increase cardiac MRI capacity at the Yorkshire Heart Centre.

Henry Procter, Jun Hui Tan, Lizette Cash, Marilena Giannoudi, Sindhoora Kotha, Sven Plein, Ananth Kidambi, Eylem Levelt, Anshuman Sengupta, Nicholas Jex

Abstract read
In one paragraph

Article in European heart journal. Imaging methods and practice, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Henry ProcterDepartment of Cardiology, Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds LS1 3EX, United Kingdom.ORCID https://orcid.org/0000-0002-9340-9838
Jun Hui TanDepartment of Cardiology, Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds LS1 3EX, United Kingdom.
Lizette CashDepartment of Cardiology, Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds LS1 3EX, United Kingdom.
Marilena GiannoudiDepartment of Cardiology, Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds LS1 3EX, United Kingdom.ORCID https://orcid.org/0000-0002-5771-7737
Sindhoora KothaDepartment of Cardiology, Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds LS1 3EX, United Kingdom.ORCID https://orcid.org/0000-0001-6853-3231
Sven PleinDepartment of Cardiology, Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds LS1 3EX, United Kingdom.ORCID https://orcid.org/0000-0002-0997-4384
Ananth KidambiDepartment of Cardiology, Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds LS1 3EX, United Kingdom.ORCID https://orcid.org/0000-0002-0939-7900
Eylem LeveltDepartment of Cardiometabolic Imaging, Baker Heart and Diabetes Institute, Melbourne, Australia.ORCID https://orcid.org/0000-0002-3799-7102
Anshuman SenguptaDepartment of Cardiology, Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds LS1 3EX, United Kingdom.ORCID https://orcid.org/0000-0002-8164-9105
Nicholas JexDepartment of Cardiology, Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds LS1 3EX, United Kingdom.ORCID https://orcid.org/0000-0001-9395-584X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

There are rising demands for cardiovascular magnetic resonance imaging (CMR) worldwide. Thoracic aorta assessment is a common CMR indication. There are many benefits to shorter scan times including improved patient experience, as well as efficiency of a service. This service development project aimed to optimize the current 'aorta' protocol in a large tertiary CMR centre in the United Kingdom (which includes aortic valve [AV] and left ventricle [LV] assessment), with the aim to reduce scanning and reporting times. A 'Short aorta' protocol was devised (where only the thoracic aorta is assessed). The 'Short aorta' protocol requires a 30-minute scan slot, whereas the 'Full aorta' protocol (assessing thoracic aorta, AV and LV function) requires 60 minutes. This project retrospectively analysed clinical and scan characteristics of patients referred to the Yorkshire Heart Centre for CMR before and after introduction of a 'Short aorta' protocol. Over the two 13-week audit periods, thoracic aorta assessment was the main indication for 137 CMR referrals. Based on clinical indication, 95 (69%) could have used the 'Short aorta' protocol. After introduction of the 'Short aorta' protocol, 39 (46%) of 85 scans were protocolled as 'Short aorta'. This resulted in significantly reduced scan times compared to the original 'aorta' protocol: 18 (IQR 15, 21) vs. 37 (IQR 32, 42) minutes;

Indexed as

aortacardiovascular magnetic resonance imagingscan optimizationservice development

Identifiers

PMID42840586
PMCPMC13639367

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.