Evidence map›Paper›PMID 42839538›Full record

ArticleJournal of applied clinical medical physics2026

Evaluation of registration accuracy using short-arc cone-beam computed tomography for image-guided radiotherapy in breast cancer.

Shuhei Wada, Masahide Tominaga, Motoharu Sasaki, Koichi Yamanashi, Yoshio Iwai, Shunsuke Furutani, Yusei Shinohara, Yoshihiro Uto

Abstract readEvaluation Study
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Shuhei WadaGraduate School of Advanced Science and Technology, Tokushima University, Tokushima, Tokushima, Japan.
Masahide TominagaGraduate School of Biomedical Sciences, Tokushima University, Tokushima, Tokushima, Japan.
Motoharu SasakiGraduate School of Biomedical Sciences, Tokushima University, Tokushima, Tokushima, Japan.
Koichi YamanashiCanon Medical Systems Corporation, Otawara, Tochigi, Japan.
Yoshio IwaiResearch Physics, Minato-ku, Tokyo, Japan.
Shunsuke FurutaniDepartment of Radiology, Tokushima Municipal Hospital, Tokushima, Tokushima, Japan.
Yusei ShinoharaGraduate School of Technology, Industrial and Social Sciences, Tokushima University, Tokushima, Tokushima, Japan.
Yoshihiro UtoGraduate School of Technology, Industrial and Social Sciences, Tokushima University, Tokushima, Tokushima, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundImage-guided radiotherapy (IGRT) using cone-beam computed tomography (CBCT) enables highly accurate imaging registration; however, increased radiation exposure remains a concern. Recently, short-arc CBCT (SA-CBCT), which reduces projection data and reconstructs images, has become available. Although previous studies have shown that image quality deteriorates when projection data are reduced, no study has directly evaluated the clinical usefulness of SA-CBCT or its effect on registration accuracy. PURPOSE: We verified the registration accuracy of SA-CBCT in breast tangential irradiation using an anthropomorphic phantom and clinical data, and examined its clinical feasibility compared with the commonly used 200° scan.

methodsAn anthropomorphic phantom was placed on the treatment bed, and CT and CBCT images acquired during treatment planning were aligned. Bed movement was measured for both conventional CBCT and SA-CBCT images. The difference between the two measurements was quantified as N, defined as the norm of the vector difference between CBCT and SA-CBCT registration shifts, to evaluate registration accuracy. The acquisition angle was varied to assess the effects of central and total angles. In the clinical study, registration data from 30 consecutive patients who underwent whole-breast irradiation were analyzed. Data were reconstructed by changing the acquisition angle from 200° to 120°, and N was calculated as in the phantom experiment.

resultsIn the phantom experiment, N was within 0.15 mm (3-axis) and 0.55 mm (6-axis) when the acquisition angle was reduced to 120°. In clinical data, the average N was 0.64 mm in 3-axis registration (84.7% within 1 mm) and 0.85 mm in 6-axis registration (71.3% within 1 mm). Even with a 120° acquisition angle, the body contour and chest wall edges were sufficiently preserved.

conclusionsSA-CBCT maintained adequate registration accuracy in breast tangential irradiation. These findings suggest its clinical applicability with appropriate acquisition angle settings.

Indexed as

Breast NeoplasmsCone-Beam Computed TomographyImage Processing, Computer-AssistedPhantoms, ImagingRadiotherapy, Image-GuidedRadiotherapy Planning, Computer-AssistedFemaleHumansOrgans at RiskPrognosisRadiotherapy DosageRadiotherapy, Intensity-Modulatedcone‐beam computed tomographyimage‐guided radiotherapyshort arc

Identifiers

PMID42839538
PMCPMC13643054

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.