Evidence map›Paper›PMID 42839277›Full record

ArticleBMC musculoskeletal disorders2026

A novel stacked double-plate fixation with quadrilateral surface buttress screws for osteoporotic acetabular fractures in elderly patients: a prospective pilot case series study evaluating clinical and radiological outcomes.

Mahmoud Abdel Karim, Ahmed Farahat, Mahmoud Fahmy

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Mahmoud Abdel KarimPelvis Fracture and Arthroplasty Unit, Orthopaedic Department, Kasr Alainy Hospital, Cairo University, Cairo, Egypt.ORCID http://orcid.org/0000-0002-3134-5402
Ahmed FarahatPelvis Fracture and Arthroplasty Unit, Orthopaedic Department, Kasr Alainy Hospital, Cairo University, Cairo, Egypt.ORCID http://orcid.org/0000-0001-8253-8127
Mahmoud FahmyPelvis Fracture and Arthroplasty Unit, Orthopaedic Department, Kasr Alainy Hospital, Cairo University, Cairo, Egypt. mahmoudfahmy1986@gmail.com.ORCID http://orcid.org/0000-0002-5700-493X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAcetabular fractures in the elderly present unique challenges due to osteoporotic bone, comminution, and frequent involvement of the quadrilateral surface (QLS) and anterior column. Conventional fixation often fails in this population, leading to hardware complications and secondary displacement. This prospective pilot study evaluates the clinical and radiological outcomes of a novel stacked double-plate technique combined with QLS buttress screws in geriatric patients.

methodsTwelve consecutive patients aged ≥ 70 years with displaced acetabular fractures involving the anterior column and QLS were treated between 2018 and 2022. All patients underwent the stacked double-plate technique with QLS buttress screws via a Modified Stoppa approach. Operative time, blood loss, complications, radiological reduction (Matta criteria), fracture union, and postoperative functional outcomes were prospectively recorded.

resultsThe cohort included 12 patients (mean age 74 ± 5 years; range 70-85). Fracture patterns were anterior column with quadrilateral plate (n = 6), associated both-column fractures (n = 4), and transverse fractures (n = 2). Mean operative time was 145 ± 18 min, and mean blood loss was 280 ± 65 mL. At a mean follow-up of 14 months (range 6-30), all fractures achieved union. Reduction quality was anatomical in 10 patients and satisfactory in 2. Final functional outcomes were favorable, with a mean HHS of 88 ± 5 (95% CI: 83-93) and mean total WOMAC of 12 ± 4 (95% CI: 8-16). No complications or hardware failures were observed.

conclusionIn this prospective pilot case series, the stacked double-plate technique with QLS buttress screws was feasible, provided stable fixation, and was associated with stable fixation and satisfactory functional outcomes in elderly patients with osteoporotic acetabular fractures. These preliminary findings should be interpreted cautiously due to the limited sample size, absence of a control group, and relatively short follow-up. Further studies with larger cohorts, comparative designs, and biomechanical validation are warranted.

Indexed as

AcetabulumBone PlatesBone ScrewsFracture Fixation, InternalOsteoporotic FracturesAgedAged, 80 and overFemaleHumansMalePilot ProjectsProspective StudiesTreatment OutcomeAnterior columnButtress screwGeriatric acetabular fracturesOsteoporotic boneQuadrilateral plateStacked double-plate technique

Identifiers

PMID42839277
PMCPMC13640349

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.