Evidence map›Paper›PMID 42836043›Full record

ArticleRadiology research and practice2026

The Establishment of National Diagnostic Reference Levels for Pediatric Chest X-Ray Examinations in Ethiopia.

Leul Adane Chemeda, Seife Teferi Dellie, Getu Ferenji, Daniel Zewdneh Solomon, Marema Jebessa Kumsa, Solomon Getachew

Abstract read
In one paragraph

Article in Radiology research and practice, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Leul Adane ChemedaDepartment of Radiology College of Health Sciences Addis Ababa University Addis Ababa Ethiopia aau.edu.et.ORCID https://orcid.org/0009-0009-4485-5979
Seife Teferi DellieDepartment of Radiology College of Health Sciences Addis Ababa University Addis Ababa Ethiopia aau.edu.et.ORCID https://orcid.org/0000-0002-3655-6671
Getu FerenjiDepartment of Internal Medicine St. Paul's Hospital Millennium Medical College Addis Ababa Ethiopia sphmmc.edu.et.
Daniel Zewdneh SolomonDepartment of Radiology College of Health Sciences Addis Ababa University Addis Ababa Ethiopia aau.edu.et.ORCID https://orcid.org/0000-0001-6487-4426
Marema Jebessa KumsaDepartment of Medical Radiologic Technology College of Health Sciences Addis Ababa University Addis Ababa Ethiopia aau.edu.et.ORCID https://orcid.org/0000-0002-6547-2936
Solomon GetachewDepartment of Technology and Innovation Management Adama Science and Technology University Adama Ethiopia astu.edu.et.ORCID https://orcid.org/0009-0002-1865-251X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: It is well established that diagnostic X-ray practices must be optimized to keep patient radiation dose as low as possible with providing the diagnostic information required. The International Commission on Radiological Protection recommends diagnostic reference levels as a practical means to optimize radiation doses in diagnostic radiology and nuclear medicine. The aim of this study was to propose national diagnostic reference levels for routine pediatric chest X-ray examinations in Ethiopia. Methods: Anthropometric and radiographic parametric data were collected from 975 patients. A standard patient was defined based on the mean values of weight, height, and BMI for the age groups of 5 to 10 and 10 to 15 years old. The exposure parameter, entrance surface air kerma, was calculated. NDRLs for entrance surface air kerma were defined as the 75 Results: The suggested national diagnostic reference levels of chest X-ray examinations were 0.07 mGy and 0.53 mGy for age groups 5-< 10 and 10-< 15, respectively. Conclusion: The 75th percentile of dose values determined in this study was higher than those published in the literature. The findings reveal significant variability in ESD across hospitals, primarily due to the use of inappropriate radiological parameters. A notable inconsistency in the selection of kV and mAs parameters was also observed, underscoring the need for standardized radiological protocols.

Indexed as

chest X-raydose optimizationentrance surface air kermanational diagnostic reference levelspediatric

Identifiers

PMID42836043
PMCPMC13637082

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.