Evidence map›Paper›PMID 42835896›Full record

ArticleTechnical innovations & patient support in radiation oncology2026

Clinical evaluation of three deep learning contouring models for head and neck organs at risk and lymph node levels.

Adam Miovecz, Bettina Nagy, Daniel Gugyeras, Daniel Fajtai, David Sipos, Csaba Vandulek, Arpad Kovacs, Ferenc Lakosi

Abstract read
In one paragraph

Article in Technical innovations & patient support in radiation oncology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Adam MioveczDepartment of Medical Imaging, Faculty of Health Sciences, University of Pecs, Kaposvar, 7400, Hungary.
Bettina NagyDepartment of Radiation Oncology, Dr. Jozsef Baka Center, Moritz Kaposi General Hospital, Kaposvar, 7400, Hungary.
Daniel GugyerasDepartment of Radiation Oncology, Dr. Jozsef Baka Center, Moritz Kaposi General Hospital, Kaposvar, 7400, Hungary.
Daniel FajtaiMedicopus Non Profit Ltd., Kaposvar, Hungary.
David SiposDepartment of Medical Imaging, Faculty of Health Sciences, University of Pecs, Kaposvar, 7400, Hungary.
Csaba VandulekDepartment of Medical Imaging, Faculty of Health Sciences, University of Pecs, Kaposvar, 7400, Hungary.
Arpad KovacsDepartment of Medical Imaging, Faculty of Health Sciences, University of Pecs, Kaposvar, 7400, Hungary.
Ferenc LakosiDepartment of Medical Imaging, Faculty of Health Sciences, University of Pecs, Kaposvar, 7400, Hungary.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Our aim was to compare the accuracy and clinical acceptability of head and neck organs at risk (OAR) and lymph node contours generated by three commercially available deep learning contouring (DLC) models: Mirada DLCExpert (Model D), Limbus AI (Model L), and MVision AI Contour+ (Model C). Methods: Seven OARs and cervical lymph node levels I to V were delineated by each model on twenty retrospectively selected patients with hypopharyngeal/laryngeal tumors (2020 to 2023). Automated contours were compared against expert reference contours using the Dice similarity coefficient (DSC), the 95th percentile Hausdorff distance (HD95), the median surface distance (MDSD) and the Jaccard index. Differences among the three models were tested with the Friedman test followed by pairwise Wilcoxon signed-rank tests with Holm-Bonferroni correction; agreement of structure volumes with the expert reference was tested with the Wilcoxon signed-rank test. A structured qualitative assessment classified each contour as requiring major corrections, minor corrections, or acceptable as is. A sensitivity analysis repeated every comparison using only reference contours independent of all three models. Results: Pooled over the seven OARs, mean DSC was 0.85 for Models L and C and 0.80 for Model D, but this ordering is produced entirely by the esophagus and the spinal canal, for which Model D applies a different anatomical definition (mean DSC 0.40 and 0.57, with model volumes 35% and 44% of the expert volume). Across the other five OARs Model D was the most accurate (0.92 against 0.84 and 0.85). After Holm-Bonferroni correction, Models L and C did not differ on any structure or metric. For lymph node levels no overlap metric separated the models in the primary analysis (all Conclusion: All three models produced contours of clinically usable quality apart from Model D on the esophagus and the spinal canal. Models L and C were not statistically different throughout. Model D differed from both on the esophagus and the spinal canal, where it applies a narrower anatomical definition, and was the most accurate model on the remaining five OARs, though that advantage was only partly confirmed when the analysis was restricted to reference contours independent of the models. Model C gave the most predictable lymph node output: the narrowest spread and the only volumes not differing significantly from the expert reference. Deep learning contouring models significantly improve head and neck treatment planning efficiency by providing clinically acceptable accuracy in a fraction of the time required for manual contouring.

Indexed as

AIDeep LearningH&NLymph node

Identifiers

PMID42835896
PMCPMC13635919

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked