Evidence map›Paper›PMID 42834950›Full record

ArticleFrontiers in dental medicine2026

Impact of laser modification on the contact angle and surface wettability of hydroxyapatite-coated PEEK implant material.

Stuti Mishra, Nayana Prabhu, Pradeep Sherigar, Veene Hegde, Vaishnavi M Nayak, Sharon Saldanha

Abstract read
In one paragraph

Article in Frontiers in dental medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Stuti MishraDepartment of Prosthodontics and Crown & Bridge, Manipal College of Dental Sciences, Manipal Academy of Higher Education, Manipal, India.
Nayana PrabhuDepartment of Prosthodontics and Crown & Bridge, Manipal College of Dental Sciences, Manipal Academy of Higher Education, Manipal, India.
Pradeep SherigarDepartment of Prosthodontics and Crown & Bridge, Manipal College of Dental Sciences, Manipal Academy of Higher Education, Manipal, India.
Veene HegdeDepartment of Prosthodontics and Crown & Bridge, Manipal College of Dental Sciences, Manipal Academy of Higher Education, Manipal, India.
Vaishnavi M NayakDepartment of Prosthodontics and Crown & Bridge, Manipal College of Dental Sciences, Manipal Academy of Higher Education, Manipal, India.
Sharon SaldanhaDepartment of Prosthodontics and Crown & Bridge, Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education, Manipal, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Polyetheretherketone (PEEK) is increasingly used in dental implantology because of its biomimetic properties. However, its application is limited by bio-inertness and inherent hydrophobicity, which may affect early biological interactions. PEEK surfaces are often coated with bioactive materials such as hydroxyapatite (HA), but it remains unclear how subsequent surface modification techniques such as laser treatment affect their wettability. There is still limited data on blood surface interactions in laser-treated HA/PEEK composites. This study was designed to assess and compare the blood contact angle of HA/PEEK surfaces before and after laser modification. Materials and methods: Twenty-one HA-coated PEEK discs were evaluated, with each individual disc serving as the experimental unit for contact-angle assessment. Blood contact-angle measurements were obtained from each disc before laser treatment and repeated on the same disc following laser surface modification, resulting in paired observations. Hydroxyapatite (HA) nano powder was applied to the PEEK surfaces using friction stir processing (FSP). Fresh EDTA-anticoagulated whole blood obtained from a single donor was used as the test fluid. To minimize variability, blood was collected from the same donor and venipuncture site, and all measurements were performed by the same operator under standardized conditions. Following baseline contact-angle measurement, the HA/PEEK discs were treated using an Er,Cr:YSGG laser (2,790 nm, 1 W) for 4 s at a working distance of 10 mm under 5% water and 95% air spray, after which contact-angle measurements were repeated. Pre- and post-laser contact-angle measurements were compared using the Wilcoxon signed-rank test, with statistical significance set at Results: Pre-laser HA/PEEK surfaces exhibited lower blood contact angles than the corresponding post-laser surfaces, indicating greater wettability before laser modification. Following laser treatment, blood contact angles increased, indicating reduced wettability under the laser parameters investigated. Conclusion: The observed reduction in wettability was specific to the laser parameters evaluated in this study.

Indexed as

biomaterialscontact anglehydroxyapatitelaser surface modificationpolyetheretherketonewettability

Identifiers

PMID42834950
PMCPMC13634801

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.