Evaluation of UNI-VAC serum separator, ethylenediaminetetraacetic acid, sodium citrate, and sodium fluoride tubes: A comparison with Becton, Dickinson and Company Vacutainer tubes.

Kuenyoul Park, Joonsang Yu, Wonho Choe, Soo Jin Yoo

Abstract readComparative Study
In one paragraph

Article in PloS one, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Kuenyoul ParkDepartment of Laboratory Medicine, Hanyang University Seoul Hospital, Hanyang University College of Medicine, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0003-3950-4946
Joonsang YuDepartment of Laboratory Medicine, Sanggye Paik Hospital, Inje University College of Medicine, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0001-5344-763X
Wonho ChoeDepartment of Laboratory Medicine, Uijeongbu Eulji Medical Center, Eulji University, Uijeongbu, Republic of Korea.
Soo Jin YooDepartment of Laboratory Medicine, Uijeongbu Eulji Medical Center, Eulji University, Uijeongbu, Republic of Korea.ORCID https://orcid.org/0000-0003-1715-3487

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Errors in the preanalytical phase are influenced by several factors, including blood collection tubes. Labex, Inc. has developed UNI-VAC tubes using a separation gel formulated with fatty acid acrylamide to enhance stability. We aimed to compare the performance of the UNI-VAC tubes with Becton, Dickinson and Company Vacutainer tubes for 53 analytes. Forty adult outpatients were prospectively enrolled in the comparison study, and an additional 20 participants were included to evaluate lot-to-lot variability. Four UNI-VAC tube types (serum separator, ethylenediaminetetraacetic acid [EDTA], sodium citrate, and sodium fluoride) were compared with their Vacutainer counterparts. Comparative performance was evaluated using Passing-Bablok regression and bias criteria from the European Federation of Clinical Chemistry and Laboratory Medicine Biological Variation Database and Westgard specifications. Stability was assessed for EDTA tubes at 24 h and sodium fluoride tubes at 24-72 h (4°C storage). The lot-to-lot variability of the EDTA tubes was examined across the three UNI-VAC and two Vacutainer lots. Fifty (94%) analytes met the predefined acceptability criteria. Lactate dehydrogenase (-4.3%), mean corpuscular volume (1.5%), and mean corpuscular hemoglobin concentration (-1.0%) marginally exceeded these limits, although the differences were small and unlikely to be clinically significant. No visible gel instability or other visible tube-related issues were observed. EDTA tubes demonstrated stability after 24 h, although the basophil percentages and platelet indices showed reduced consistency. Glucose values were stable for up to 48 h but declined at 72 h in both tubes. The lot-to-lot variability of the UNI-VAC EDTA tubes was comparable to that of the Vacutainer tubes. UNI-VAC tubes show a clinical performance equivalent to that of Vacutainer tubes for most analytes, with acceptable stability. These findings indicate that UNI-VAC tubes represent a reliable alternative for clinical laboratory use, with further validation in larger patient cohorts.

Indexed as

Blood Specimen CollectionCitratesEdetic AcidSodium FluorideAdultFemaleHumansMaleMiddle AgedSodium CitrateCitratesEdetic AcidSodium CitrateSodium Fluoride

Identifiers

PMID42832515
PMCPMC13637866

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.