Evidence map›Paper›PMID 42832003›Full record

ArticleJournal of clinical monitoring and computing2026

Preoperative pulse rate variability and the hemodynamic response to tracheal intubation: a retrospective secondary analysis.

Gayeon Ryu, Jae Moon Choi, Byung-Moon Choi, Hangsik Shin

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of clinical monitoring and computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Gayeon Ryu *Department of Medical Informatics and Statistics, Brain Korea 21 Project, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Jae Moon Choi *Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Byung-Moon ChoiDepartment of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea. byungmoonchoi7@gmail.com.
Hangsik ShinDepartment of Medical Informatics and Statistics, Brain Korea 21 Project, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea. hangsik.shin@amc.seoul.kr.

Funding

Asan Institute for Life Sciences, Asan Medical Center 2024IP0021Ministry of Health & Welfare HR20C0026Ministry of Science and ICT, the Ministry of Trade, Industry and Energy, the Ministry of Health & Welfare, the Ministry of Food and Drug Safety RS-2022-00141473
6 · The paper itself

Abstract

Individual hemodynamic responses to tracheal intubation vary considerably. We examined whether preoperative pulse rate variability (PRV), a photoplethysmography-derived surrogate of heart rate variability, is associated with this response. In this retrospective secondary analysis, 183 adults undergoing elective surgery under general anesthesia were analyzed. A 3-min photoplethysmogram was recorded in the supine, resting, unsedated state immediately before induction, and time-domain (mean pulse-to-pulse interval [mean PPI], RMSSD, and pNN50) and frequency-domain (LF power, HF power, and LF/HF) PRV indices were computed. A hemodynamic response was defined as a systolic blood pressure rise >15 mmHg, or a heart rate rise to >90 beats/min or by >30% (≥ 10% if baseline ≥90 beats/min); patients were classified as response-present or response-absent. Of 183 patients, 101 (55.2%) were response-present and 82 (44.8%) response-absent. LF/HF was higher in the response-present group (1.84 [1.32-2.60] vs 1.37 [0.78-2.44]; unadjusted P = 0.018), but no index remained significant after correction for multiple comparisons (LF/HF adjusted P = 0.109; all others adjusted P ≥ 0.301). Discrimination was limited (AUC 0.602; 95% CI 0.518-0.684). In a sensitivity analysis using a blood-pressure-only response definition, no PRV index differed significantly. After correction for multiple comparisons, no preoperative PRV index differed significantly between patients with and without a hemodynamic response to tracheal intubation. LF/HF was higher in the response-present group before correction, but the effect size was small and the discriminative performance limited. These findings do not support preoperative PRV for identifying patients at risk and are hypothesis-generating only. Trial Registration number: KCT0005840.

Indexed as

Autonomic nervous systemHemodynamic responseMean pulse-to-pulse intervalPreoperative assessmentPulse rate variabilityTracheal intubation

Identifiers

PMID42832003

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.