Evidence map›Paper›PMID 42831996›Full record

ArticleJournal of robotic surgery2026

A single-port robotic platform for minimally invasive cardiac surgery: system functionality and initial preclinical feasibility.

Chengcheng Cai, Tong Ren, Zhikang Ma, Kailun Dong, Baoyue Lu, Wenze Sun, Jianchang Zhao, Jianmin Li, Rong Wang, Lizhi Pan

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of robotic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Chengcheng Cai *School of Mechanical Engineering, Tianjin University, No. 135, Yaguan Road, Jinnan District, Tianjin, 300350, China.
Tong Ren *Department of Adult Cardiac Surgery, Senior Department of Cardiology, Sixth Medical Center of People's Liberation Army General Hospital, No. 6 Fucheng Road, Haidian District, Beijing, 100048, China.
Zhikang MaSchool of Mechanical Engineering, Tianjin University, No. 135, Yaguan Road, Jinnan District, Tianjin, 300350, China.
Kailun DongSchool of Mechanical Engineering, Tianjin University, No. 135, Yaguan Road, Jinnan District, Tianjin, 300350, China.
Baoyue LuSchool of Mechanical Engineering, Tianjin University, No. 135, Yaguan Road, Jinnan District, Tianjin, 300350, China.
Wenze SunSchool of Mechanical Engineering, Tianjin University, No. 135, Yaguan Road, Jinnan District, Tianjin, 300350, China.
Jianchang ZhaoSchool of Mechanical Engineering, Tianjin University, No. 135, Yaguan Road, Jinnan District, Tianjin, 300350, China.
Jianmin LiSchool of Mechanical Engineering, Tianjin University, No. 135, Yaguan Road, Jinnan District, Tianjin, 300350, China.
Rong WangDepartment of Adult Cardiac Surgery, Senior Department of Cardiology, Sixth Medical Center of People's Liberation Army General Hospital, No. 6 Fucheng Road, Haidian District, Beijing, 100048, China. wangrongd@126.com.
Lizhi PanSchool of Mechanical Engineering, Tianjin University, No. 135, Yaguan Road, Jinnan District, Tianjin, 300350, China. melzpan@tju.edu.cn.

Funding

National Natural Science Foundation of China 52525504Natural Science Foundation of Tianjin Municipality 24JCJQJC00090
6 · The paper itself

Abstract

Conventional robotic cardiac approaches generally require multiple intercostal access sites to establish instrument triangulation. This study presents an in-house-developed single-port robotic platform designed around cardiac manipulation requirements and evaluates its initial task-specific feasibility in one pig. The system integrates a common entry guide, three-dimensional endoscopic visualization, articulated instruments, and master-slave teleoperation. Robot-assisted internal mammary artery (IMA) dissection was performed on the beating heart through retractor-assisted intercostal access. Mitral annular suture placement was performed after planned terminal euthanasia, incision enlargement, and manual atrial exposure maintained with suspension sutures. Cardiopulmonary bypass was not used. A 115-mm IMA segment was skeletonized robotically during a 49-min dissection interval within an 87-min IMA phase, followed by manual clipping and division. No additional robotic port was required, and no macroscopic IMA injury or major bleeding was observed during dissection. Mitral annular suture placement was completed at nine positions in 46 min using coordinated bimanual manipulation. These observations provide preliminary evidence that intrathoracic deployment and distal articulation can support the selected cardiac tasks under the reported conditions. The findings provide a basis for technical refinement and further preclinical evaluation but do not establish reproducibility, procedural safety, or the feasibility of a complete single-port mitral valve procedure.

Indexed as

Cardiac Surgical ProceduresMinimally Invasive Surgical ProceduresRobotic Surgical ProceduresAnimalsEquipment DesignFeasibility StudiesMammary ArteriesMitral ValveSwineInternal mammary artery dissectionMitral annular suture placementPreclinical feasibilityRobotic cardiac surgerySingle-port robotic surgery

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.