Evidence map›Paper›PMID 42831213›Full record

ArticleArthroscopy techniques2026

Hybrid Sequential Meniscal Suture Technique.

Jose Leonardo Rocha de Faria, Igor Araujo Farias, Rafael Erthal de Paula, Sandra Tie Nishibe Minamoto, Diego Ariel, Yuri Di Cavalcanti Sampaio, Naasson Trindade Cavanellas, João Antonio Matheus Guimarães, Geraldo da Rocha Motta, José Paulo Gabbi Aramburú Filho and 2 more

Abstract read
In one paragraph

Article in Arthroscopy techniques, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Jose Leonardo Rocha de FariaNational Institute of Traumatology and Orthopedics of Brazil Rio de Janeiro Rio de Janeiro Brazil.ORCID https://orcid.org/0000-0003-2635-1469
Igor Araujo FariasSchool of Medicine from University of São Paulo São Paulo Brazil.
Rafael Erthal de PaulaNational Institute of Traumatology and Orthopedics of Brazil Rio de Janeiro Rio de Janeiro Brazil.ORCID https://orcid.org/0000-0003-2112-7652
Sandra Tie Nishibe MinamotoNational Institute of Traumatology and Orthopedics of Brazil Rio de Janeiro Rio de Janeiro Brazil.
Diego ArielUniversidade Federal Rural do Semi-Árido - UFERSA Mossoró Rio Grande do Norte Brazil.ORCID https://orcid.org/0000-0002-5702-1529
Yuri Di Cavalcanti SampaioNational Institute of Traumatology and Orthopedics of Brazil Rio de Janeiro Rio de Janeiro Brazil.ORCID https://orcid.org/0000-0002-0363-3968
Naasson Trindade CavanellasNational Institute of Traumatology and Orthopedics of Brazil Rio de Janeiro Rio de Janeiro Brazil.
João Antonio Matheus GuimarãesNational Institute of Traumatology and Orthopedics of Brazil Rio de Janeiro Rio de Janeiro Brazil.
Geraldo da Rocha MottaNational Institute of Traumatology and Orthopedics of Brazil Rio de Janeiro Rio de Janeiro Brazil.
José Paulo Gabbi Aramburú FilhoNational Institute of Traumatology and Orthopedics of Brazil Rio de Janeiro Rio de Janeiro Brazil.
Camilo Partezani HelitoSchool of Medicine from University of São Paulo São Paulo Brazil.ORCID https://orcid.org/0000-0003-1139-2524
Phelippe Valente MaiaNational Institute of Traumatology and Orthopedics of Brazil Rio de Janeiro Rio de Janeiro Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Meniscal preservation is a priority in the treatment of knee injuries because of the fundamental role of the meniscus in load absorption, joint stability, and chondral protection. Several repair techniques have been described, including inside-out, outside-in, and all-inside approaches. More recently, continuous suturing techniques have emerged as a promising alternative, allowing multiple fixation points with shorter operative time and reduced costs. We describe a hybrid continuous meniscal repair technique that combines initial all-inside fixation with additional outside-in sutures using the excess suture limb from the implant. The repair begins with meniscal fixation using an all-inside device, after which the free suture end is redirected percutaneously through successive outside-in passages, creating a continuous vertical suture construct. This strategy enables multiple fixation points from a single device, potentially enhancing biomechanical stability and reducing the need for additional implants. The integration of all-inside and outside-in fixation allows the entire extent of the tear to be addressed in a safe, reproducible, and cost-effective manner. The described hybrid technique expands the applicability of continuous meniscal suturing and may contribute to improved clinical outcomes in meniscal preservation.

Identifiers

PMID42831213
PMCPMC13634664

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.