Evidence map›Paper›PMID 42829917›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2026

Fire-Safe Hierarchical Solid Polymer Electrolytes Enabled by Dual-Functional Microcapsules for Lithium Metal Batteries.

Ziqi Huang, Jiuqing Gui, Qiaoying Cao, Yong Xiao, Hang Hu, Yeru Liang

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ziqi Huang *College of Materials and Chemical Engineering, Key Laboratory for Biobased Materials and Energy of Ministry of Education, South China Agricultural University, Guangzhou, People's Republic of China.
Jiuqing Gui *College of Materials and Chemical Engineering, Key Laboratory for Biobased Materials and Energy of Ministry of Education, South China Agricultural University, Guangzhou, People's Republic of China.
Qiaoying CaoCollege of Materials and Chemical Engineering, Key Laboratory for Biobased Materials and Energy of Ministry of Education, South China Agricultural University, Guangzhou, People's Republic of China.
Yong XiaoCollege of Materials and Chemical Engineering, Key Laboratory for Biobased Materials and Energy of Ministry of Education, South China Agricultural University, Guangzhou, People's Republic of China.
Hang HuCollege of Materials and Chemical Engineering, Key Laboratory for Biobased Materials and Energy of Ministry of Education, South China Agricultural University, Guangzhou, People's Republic of China.
Yeru LiangCollege of Materials and Chemical Engineering, Key Laboratory for Biobased Materials and Energy of Ministry of Education, South China Agricultural University, Guangzhou, People's Republic of China.ORCID https://orcid.org/0000-0002-6169-9981

Funding

China Scholarship Council 202408440282Guangdong Basic and Applied Basic Research Foundation 2024B1515020017Guangzhou Basic and Applied Basic Research Foundation 2025A04J7131National Natural Science Foundation of China 52373074
6 · The paper itself

Abstract

Lithium metal batteries offer high energy density but suffer from severe safety risks associated with dendrite growth and flammable electrolytes, which can lead to thermal runaway and combustion. Although solid-state electrolytes improve thermal stability, they primarily rely on intrinsic nonflammability and remain ineffective in suppressing combustion once thermal runaway is triggered. Here, we report a dual-functional fire-safe microcapsule-enabled strategy to construct hierarchical solid polymer electrolytes (HSPEs) with integrated fire-suppression capability. Fire-extinguishing agents, perfluoro(2-methyl-3-pentanone), are encapsulated within ammonium hydrogen phytate-modified urea-formaldehyde-based resin shells and incorporated into an ethylene-vinyl acetate matrix. Upon thermal stimulation, the microcapsules undergo rapid structural rupture, releasing perfluoro(2-methyl-3-pentanone) to suppress combustion, while the ammonium hydrogen phytate-derived shell forms a protective char layer that retards heat and mass transfer. This dual-functional design enables thermally triggered fire suppression within the electrolyte framework. Importantly, the HSPEs maintain desirable electrochemical properties, including a room-temperature ionic conductivity of 0.64 mS cm

Indexed as

active fire protectionammonium hydrogen phytatedual‐functional fire‐safe microcapsuleshierarchical solid polymer electrolyteslithium metal batteries

Identifiers

PMID42829917
PMCPMC13634469

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.