Evidence map›Paper›PMID 42828710›Full record

ArticleRadiological physics and technology2026

Inter-software variability in CT organ-dose calculation under identical scan conditions: implications for users and dose evaluation in the Japanese population.

Toshioh Fujibuchi, Donghee Han, Choirul Anam

Abstract read
PubMed Publisher
In one paragraph

Article in Radiological physics and technology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Toshioh FujibuchiDivision of Medical Quantum Science, Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. fujibuchi.toshioh.294@m.kyushu-u.ac.jp.ORCID http://orcid.org/0000-0001-9713-6155
Donghee HanDepartment of Radiological Science, Kangwon National University, Samcheok, 25949, Republic of Korea.
Choirul AnamDepartment of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Semarang, Central Java, Indonesia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Organ dose calculation software offers a convenient way to estimate organ and effective doses in computed tomography (CT) for radiation risk assessment. However, even under identical scan conditions the estimates differ among software packages, and users must understand these differences when applying the results. We quantified the magnitude and causes of inter-software differences and evaluated typical doses for the Japanese population. Three packages-NCICT, WAZA-ARI v2, and VirtualDose CT-were compared under identical conditions (120 kV, 1 s rotation, pitch 1, no tube current modulation) for head, chest, and abdomen-pelvis scans. Tube current was matched to the national median dose indices (Japan DRLs 2025), and the body size to the Japanese adult average (male 170 cm/70 kg; female 160 cm/50 kg). Excluding muscle, organ doses differed among software by up to 28% (male) and 47% (female) relative to WAZA-ARI v2. Muscle was a separate outlier: the muscle dose from the size-adjustable phantom of NCICT was about 90% lower than that from the other two packages. Scanner-dependent differences appeared only in WAZA-ARI v2 (up to 19%), and a ± 2 cm change in scan position markedly altered doses to organs at the scan boundary. Effective doses for the Japanese population were approximately 2.2 mSv (head), 9.6 mSv (chest), and 13.0 mSv (abdomen-pelvis), all within the ranges reported by UNSCEAR 2020/2021. Because all packages have been examined against measurements previously, these differences arise from phantom anatomy and size and from calculation algorithms rather than from inaccuracy; users should interpret results with awareness of this variability.

Indexed as

Anthropomorphic phantomComputed tomographyDose calculation softwareEffective doseMonte Carlo simulationOrgan dose

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.