Evidence map›Paper›PMID 42827701›Full record

ArticleFrontiers in dental medicine2026

Effect of 3D-printed model base height on thickness distribution of thermoformed zendura FLX dual-layer clear aligners: an

Thi-Bich-Van Tran, Ngoc-Anh-Thu Pham

Abstract read
In one paragraph

Article in Frontiers in dental medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Thi-Bich-Van TranFaculty of Dentistry, University of Medicine and Pharmacy at Ho Chi Minh City, Vietnam.
Ngoc-Anh-Thu PhamFaculty of Dentistry, University of Medicine and Pharmacy at Ho Chi Minh City, Vietnam.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Thermoforming of clear aligners causes non-uniform material thinning that may influence the structural and mechanical characteristics of the aligners. While greater model base height (MBH) has been shown to increase thinning in single-layer aligners, its effect on dual-layer materials remains unclear. This study aimed to evaluate the effect of four MBH levels (2, 4, 6, and 8 mm) on the thickness distribution of thermoformed Zendura FLX dual-layer clear aligners. Methods: Forty Zendura FLX aligners were thermoformed over standardized 3D-printed maxillary models with MBH of 2, 4, 6, and 8 mm ( Results: EMM thickness decreased progressively with increasing MBH: 446 µm (95% CI 432-460) at MBH 2 mm, 386 µm (95% CI 374-399) at MBH 4 mm, 329 µm (95% CI 319-340) at MBH 6 mm, and 268 µm (95% CI 260-277) at MBH 8 mm (all pairwise comparisons Conclusions: Increasing MBH resulted in a progressive reduction in the thickness of thermoformed Zendura FLX dual-layer clear aligners across all tooth types and measurement sites. Among the four levels tested, an MBH of approximately 4 mm appeared to provide a more balanced thickness distribution. These findings suggest that MBH should be considered as an important fabrication parameter in clear aligner production.

Indexed as

clear alignersdual-layer alignersmodel base heightthermoformingthickness distribution

Identifiers

PMID42827701
PMCPMC13630649

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.