Evidence map›Paper›PMID 42824356›Full record

ArticleCardiology research and practice2026

Comparison of Sizing Methods to Optimize Device Selection for Percutaneous Closure of Atrial Septal Defects.

Çağdaş Vural, Ali Baykan, Alper Doğan, Yunus Emre Kum, Özge Pamukçu Akay, Kazım Üzüm, Nazmi Narin

Abstract read
In one paragraph

Article in Cardiology research and practice, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Çağdaş VuralPediatric Cardiology Department Medical Faculty Mustafa Eraslan Children Hospital Erciyes University Melikgazi Kayseri 38030 Turkey erciyes.edu.tr.ORCID https://orcid.org/0000-0003-2734-0972
Ali BaykanPediatric Cardiology Department Medical Faculty Mustafa Eraslan Children Hospital Erciyes University Melikgazi Kayseri 38030 Turkey erciyes.edu.tr.ORCID https://orcid.org/0000-0002-6760-3936
Alper DoğanEskişehir City Hospital, 71 Evler Neighborhood Çavdarlar Street Odunpazarı, Eskişehir 26080, Turkey.ORCID https://orcid.org/0000-0002-5735-9255
Yunus Emre KumPediatric Cardiology Department Aksaray University Training and Research Hospital Aksaray 68000 Turkey.ORCID https://orcid.org/0000-0002-7089-0585
Özge Pamukçu AkayPediatric Cardiology Department Medical Faculty Marmara University Pendik Training and Research Hospital Marmara University Pendik İstanbul Turkey marmara.edu.tr.ORCID https://orcid.org/0000-0003-3321-2387
Kazım ÜzümPediatric Cardiology Department, Acıbadem Hospital- KAYSERİ, Mustafa Kemal Paşa Blv. No:1 Seyitgazi Melikgazi, Kayseri 38030, Turkey.ORCID https://orcid.org/0000-0001-8194-6444
Nazmi NarinPediatric Cardiology Department Medical Faculty İzmir Kâtip Çelebi University Çiğli İzmir 35620 Turkey.ORCID https://orcid.org/0000-0003-2713-364X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Aims: Accurate sizing of atrial septal defects (ASDs) is crucial for appropriate device selection during percutaneous transcatheter closure. Despite the availability of multiple imaging and sizing techniques, no consensus exists on the optimal method for determining device size. This study aimed to compare preprocedural ASD measurements obtained using different techniques with the final device waist diameter and to identify the measurement method demonstrating the most favorable agreement and reproducibility. Methods: This retrospective study included 149 pediatric patients (64 males, 85 females) who underwent percutaneous transcatheter ASD closure. Preprocedural defect sizing was performed using transthoracic echocardiography (TTE), balloon sizing, and transesophageal echocardiography (TEE). TEE measurements were obtained in the four-chamber, aortic, and bicaval views. In addition to individual diameters, the arithmetic mean, cube root-derived diameter, and maximal TEE-measured diameter were calculated and compared with the final device waist diameter. The final device waist diameter, measured fluoroscopically after deployment, was used as the reference comparator, reflecting operator-selected device sizing rather than true anatomical defect dimensions. Results: Among TEE-based measurements, both the cube root-derived diameter and the arithmetic mean of TEE measurements demonstrated high reproducibility and favorable agreement with the final device waist diameter, with only marginal numerical differences between the two methods. Bland-Altman analysis supported these findings by showing minimal bias and narrow limits of agreement, whereas TTE and balloon sizing demonstrated lower, though statistically significant, concordance with the final device waist diameter. Conclusion: Combining multiple measurement techniques improves agreement with the operator-selected device size during percutaneous ASD closure. While TTE alone may be sufficient in patients with simple defects and adequate acoustic windows, integrated approaches incorporating TEE and multiaxis measurements showed favorable agreement characteristics, particularly in anatomically heterogeneous defects or resource-limited settings. These findings should be interpreted as reflecting agreement with operator-selected device sizing rather than anatomical sizing accuracy, given the inherent circularity of using implanted device size as a reference standard.

Indexed as

atrial septal defect (ASD)congenital heart diseasesinterventional cardiologysizing methodstranscatheter closure

Identifiers

PMID42824356
PMCPMC13627864

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked