Evidence map›Paper›PMID 42820987›Full record

ArticleHernia : the journal of hernias and abdominal wall surgery2026

Self-gripping mesh without fixation versus anatomical mesh with tack fixation for laparoscopic TAPP inguinal hernia repair: a retrospective cohort study.

Guvenc Diner, Guven Erdogrul, Boran Cihat Karakus, Mehmet Hatip Adıguzel

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Hernia : the journal of hernias and abdominal wall surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Guvenc DinerDeparment of General Surgery, Mersi̇n Sehir Research and Training Hospital, Mersin, Türkiye. guvencdiner@yahoo.com.ORCID http://orcid.org/0000-0002-7732-4092
Guven ErdogrulDeparment of General Surgery, Mersi̇n Sehir Research and Training Hospital, Mersin, Türkiye.
Boran Cihat KarakusDeparment of General Surgery, Mersi̇n Sehir Research and Training Hospital, Mersin, Türkiye.
Mehmet Hatip AdıguzelDeparment of General Surgery, Mersi̇n Sehir Research and Training Hospital, Mersin, Türkiye.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMesh characteristics and fixation techniques may influence operative efficiency, postoperative pain, and resource utilization during laparoscopic trans-abdominal preperitoneal (TAPP) inguinal hernia repair. However, comparisons between self-gripping and anatomically contoured meshes may be inherently confounded when a self-gripping mesh is used without mechanical fixation, whereas an anatomical mesh is routinely fixed. We therefore compared these two routinely used mesh-fixation strategies in patients undergoing primary unilateral TAPP repair.

methodsWe retrospectively reviewed 346 patients who underwent primary unilateral conventional laparoscopic TAPP repair between January 2022 and December 2025. Patients were treated using either a self-gripping mesh without additional mechanical fixation (n = 157) or an anatomically contoured mesh secured with absorbable tack fixation (n = 189). The primary outcome was skin-to-skin operative duration. Secondary outcomes included postoperative pain at 6 and 24 h, hospital length of stay, postoperative complications, 12-month recurrence, and direct material costs. Multi-variable linear regression was performed to identify factors independently associated with operative duration. Given the low number of observed complications, an exploratory multi-variable logistic regression analysis was performed and interpreted cautiously.

resultsMean operative duration was significantly shorter in the self-gripping group than in the anatomical mesh with tack fixation group (52.7 ± 15.9 vs. 61.7 ± 19.2 min, respectively; p < 0.001). Postoperative VAS scores were lower in the self-gripping group at both 6 h (5.0 ± 1.2 vs. 6.1 ± 1.4; p < 0.001) and 24 h (5.6 ± 1.3 vs. 6.7 ± 1.5; p < 0.001). Mean hospital length of stay was 1.2 ± 0.4 versus 1.4 ± 0.5 days (p < 0.001), although the absolute difference was modest. Total direct material costs were significantly lower with the self-gripping strategy ($141.2 ± 5.1 vs. $192.2 ± 12.2; p < 0.001), primarily because no disposable fixation device was required. Postoperative complications were uncommon and did not differ significantly between groups (1.9% vs. 3.2%; p = 0.509). At 12 months, one recurrence occurred in the anatomical mesh group and none in the self-gripping group (0.0% vs. 0.5%; p = 1.000).

conclusionsIn this retrospective cohort, the self-gripping mesh/no-fixation strategy was associated with shorter operative duration, lower early postoperative pain scores, and lower direct material costs than the anatomical mesh/tack-fixation strategy. These findings should be interpreted as differences between two combined mesh-fixation strategies rather than as evidence that one mesh design is intrinsically superior to the other. Larger prospective comparative studies are needed to determine the independent contributions of mesh design and fixation technique.

Indexed as

Hernia, InguinalHerniorrhaphyLaparoscopySurgical MeshAdultAgedFemaleHumansLength of StayMaleMiddle AgedOperative TimePostoperative ComplicationsPostoperative PainRecurrenceRetrospective StudiesAnatomical meshInguinal herniaLaparoscopic TAPPMaterial costMesh fixationOperative timePostoperative painSelf-gripping mesh

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.