ArticleAnnals of medicine2026
Vision transformer-based ordinal model for semi-quantitative synovitis grading on musculoskeletal ultrasound: a retrospective study with internal and external validation.
Article in Annals of medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTo develop and validate a Vision Transformer-based model for semi-quantitative grading of synovitis on musculoskeletal ultrasound and to assess its potential clinical utility. The study also examined whether transformer-based modeling offers advantages over conventional CNNs in ordinal ultrasound grading. PATIENTS: This retrospective diagnostic study included 312 patients, 624 joints, and 1,248 ultrasound images, which were divided at the patient level into training, validation, internal test, and external test cohorts. A Swin Transformer-based ordinal grading model was trained on gray-scale and power Doppler ultrasound data and compared with CNN baselines using internal validation, external testing, stratified subgroup analysis, interpretability assessment, and a reader-assistance evaluation.
resultsThe Vision Transformer achieved the best overall performance, with an internal-test accuracy of 0.809, macro F1 score of 0.806, weighted kappa of 0.842, and AUC of 0.929, while evaluation on an external test set, curated from a non-overlapping period at the same institution, remained acceptable with an accuracy of 0.771 and AUC of 0.904. Most errors occurred between adjacent grades, multimodal GSUS plus PDUS input outperformed single-modality models, and AI assistance improved junior-reader agreement and efficiency.
conclusionsThis preliminary study confirms that Vision Transformer can achieve accurate and clinically applicable synovitis grading on musculoskeletal ultrasound, showing better robustness than traditional CNNs. This method may help standardize and streamline ultrasound evaluation in clinical practice and multicenter studies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.