Characterization and Mitigation of Boundary Sampling Artifacts in Electron Phase Space Generation for Clinical FLASH-RT Deployment.
Article in ArXiv, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Background: Clinical implementation of Monte Carlo (MC)-based treatment planning for electron FLASH radiotherapy requires computationally efficient phase space (PHSP) generation strategies to meet the planning timelines of ultra-high-dose-rate (UHDR) delivery. Applicator-specific PHSP files, recorded at the aperture exit, reduce dose calculation time by 30-50% relative to traditional placement at the linac-exit window, enabling clinically practical planning cycles for FLASH treatment planning system (TPS) deployment. However, positioning PHSP scoring planes coincident with the applicator-air interface introduces boundary sampling artifacts that have not been previously characterized in the electron PHSP literature. Purpose: To identify and characterize a boundary sampling artifact arising in Geant4-based Monte Carlo simulations when PHSP scoring planes are positioned coincident with material-air interfaces, and to demonstrate its mitigation through systematic scoring plane offset, enabling clinical deployment of applicator-specific electron beam PHSP libraries for FLASH-RT treatment planning. Methods: Applicator-specific PHSP files were generated using GAMOS 6.2.0 for a commissioned 9 MeV Mobetron UHDR Monte Carlo model across twelve clinical aperture configurations (2.5-10 cm diameter) intended for deployment in the GMV Radiance treatment planning system. The scoring plane sensitivity analysis was performed on the A6 short cone (aperture exit at 397 mm) across three positions: coincident with the material-air interface (397 mm), 0.1 mm downstream (397.1 mm), and 1 mm downstream (398 mm). The corresponding 1 mm offset was subsequently applied to the A10 long cone (aperture exit at 406 mm, scoring plane at 407 mm) for global validation. Dose calculations were benchmarked against linac-exit PHSP references and experimental water phantom measurements via distance-to-agreement (DTA) analysis against the 3 mm clinical acceptance criterion established by AAPM TG-105. Results: Scoring at the exact interface produced systematic proximal R50 shifts of up to 2.2 mm and DTA values of 4-6 mm for small-aperture configurations, exceeding the clinical acceptance criterion and rendering the PHSP library unsuitable for clinical deployment. A 0.1 mm offset partially corrected the angular distribution at the boundary but failed to resolve the energy-loss artifact affecting the distal falloff region. A 1 mm offset fully resolved all artifacts, achieving mean DTA values of 1.45 ± 0.63 mm (A6 series PDDs) and 2.00 ± 0.61 mm (A10 series PDDs), equivalent to or better than the linac-exit reference across all twelve configurations. Conclusions: Boundary sampling artifacts in Geant4-based PHSP generation arise from the degenerate behavior of the fUseSafety step-limitation algorithm when safety = 0 at exact material boundaries, producing incomplete secondary electron equilibration and a systematic energy-loss artifact in the scored particle population that manifests as a proximal shift of the distal dose falloff. A 1 mm downstream offset fully mitigates these artifacts while introducing negligible perturbation to primary beam characteristics, enabling clinical deployment of the resulting applicator-specific PHSP library in the GMV Radiance TPS for FLASH-RT treatment planning. This offset requirement warrants investigation in other Geant4-based frameworks (including TOPAS and GATE) scoring PHSP files at applicator or collimator exit surfaces.