Evidence map›Paper›PMID 42817496›Full record

ArticleSensors (Basel, Switzerland)2026

Measuring Unintentional Force Drift: Reliability, Number of Trials, and Age-Related Differences.

Michał Pawłowski

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Michał PawłowskiInstitute of Sport Sciences, Department of Human Motor Behavior, Academy of Physical Education in Katowice, 40-065 Katowice, Poland.ORCID 0000-0002-1129-8741

Funding

Ministry of Science under the 'Regional Initiative of Excellence' programme, "Promoting Healthy Lifestyles and Extending Lifespan" RID/SP/0053/2024/01
6 · The paper itself

Abstract

Unintentional force drift (UFD) describes the decline in force that occurs when visual feedback is removed despite the intention to maintain a target force. This study determined the reliability of UFD, the number of trials required for reliable assessment, and whether reliability differed across age groups. Twenty-four healthy adults completed six trials of simultaneous bilateral upper extremity force production task (isometric elbows flexion at 20% of Maximal Voluntary Contraction under visual and no visual feedback). Relative and absolute reliability of force and force drift were assessed using intraclass correlation coefficient (ICC), standard error of measurement and minimal detectable changes. Overall, measurement reliability improved as the number of trials increased. Force showed good reliability with visual feedback and excellent reliability without visual feedback. Force drift showed moderate reliability with visual feedback and good reliability without visual feedback (ICC = 0.84). Across all participants, five trials provided a UFD measurement with good reliability. UFD measurement properties differed across age groups, with older adults showing lower ICC values, greater measurement error, and requiring more trials than younger adults. In conclusion, five trials are recommended for UFD assessment, although more trials may be required in older adults.

Indexed as

AgingAdultAgedFeedback, SensoryFemaleHumansIsometric ContractionMaleMiddle AgedReproducibility of ResultsYoung Adultintraclass correlation coefficientisometric force controlmeasurement errorvisual feedback

Identifiers

PMID42817496
PMCPMC13611340

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.