ArticleSensors (Basel, Switzerland)2026
A Portable Electrical Response Verification System for Blood Glucose Meters Based on Dynamic Microcurrent Reproduction.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Portable blood glucose meters are commonly evaluated using test strips and control solutions, which assess the combined meter-strip-reagent response but are not designed to provide a directly controlled, pre-characterized electrical stimulus for repeated meter-side verification. This study developed a portable electrical response verification system based on dynamic microcurrent reproduction using a calibrated programmable current source. At each of two control solution levels, five 1000-point test strip current responses were acquired. Each response was reduced to 100 points by averaging every 10 consecutive samples, and the five reduced responses were then averaged point by point to obtain one level-specific mean reference waveform. Each mean waveform was converted into a 100-point DAC code table for STM32-controlled reproduction. The current source provided a measured output range of 0.016-9.829 μA. Five repeated reproductions per level yielded mean Pearson correlation coefficients of 0.9993 and 0.9995 and peak current CV values of 2.52% and 1.59%, respectively. The corresponding GA-3 meter (Sinocare Inc., Changsha, Hunan, China) readings differed from the mean original readings by 1.70% and 1.18%, with CV values of 1.81% and 1.29%. These results support the feasibility of controlled electrical response verification and short-term repeatability assessment of strip-based blood glucose meters.