ArticleSensors (Basel, Switzerland)2026
Sensorless Coupling Estimation via the Input Reflection Coefficient of a Chireix Combiner for Adaptive Wearable Wireless Power Transfer.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Adaptive wireless power transfer (WPT) systems for wearable and biomedical applications require continuous knowledge of the magnetic coupling coefficient to maintain stable power delivery under motion-induced variations. Conventional approaches rely on auxiliary sensors or dedicated RF measurement stages, which increase system complexity and limit integration in compact platforms. This paper introduces a sensorless coupling estimation method based on the input reflection phase of a Chireix outphasing combiner operating in in-phase mode (φ=0°). The reflection phase ∠Γin exhibits a numerically monotonic dependence on the coupling coefficient over the wearable-relevant range k∈[0.05,0.70], arising from a structural decoupling between coupling-dependent conductance and fixed susceptive compensation in the combiner input admittance. The method enables coupling estimation using only intrinsic RF observables at the transmitter port, without interrupting power transfer or requiring additional sensing hardware, via a two-step protocol combining sub-millisecond sensing with coupling-aware outphasing control. Validation combines analytical modeling, numerical evaluation, Monte Carlo analysis under component tolerances, and circuit-level S-parameter simulation at 13.56 MHz, demonstrating robust monotonic behavior under component variations, phase noise, and resonant detuning. The framework reinterprets the Chireix combiner as a dual-function structure enabling simultaneous power combining and coupling observability, providing a low-overhead solution for adaptive wearable WPT systems.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.