Evidence map›Paper›PMID 42817312›Full record

ArticleSensors (Basel, Switzerland)2026

Physics-Informed Design and Bench/Phantom Validation of a Shaft-Compatible 13.56 MHz NFC System for Laparoscopic Colorectal Tumour Localisation.

Bogdan Mocan, Mihaela Mocan, Mircea Fulea, Mircea Murar, Zsolt Mate, Adrian Calborean, Vasile V Bintintan

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Bogdan MocanDepartment of Engineering Design and Robotics, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania.ORCID 0000-0002-2488-7254
Mihaela MocanDepartment of Internal Medicine, Iuliu Hațieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania.ORCID 0000-0001-5906-8024
Mircea FuleaDepartment of Engineering Design and Robotics, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania.ORCID 0000-0001-9640-6379
Mircea MurarDepartment of Engineering Design and Robotics, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania.ORCID 0000-0001-6206-0533
Zsolt MateDepartment of Circuit Design, Tehnologistic, 407035 Cluj-Napoca, Romania.
Adrian CalboreanNational Institute for Research and Development of Isotopic and Molecular Technologies, Donath Street, No 67-103, 400293 Cluj-Napoca, Romania.ORCID 0000-0003-2779-5643
Vasile V BintintanDepartment of Surgery, 1st Clinic of Surgery, Iuliu Hatieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania.

Funding

the Romanian Ministry of Research, Innovation and Digitization, CCCDI-UEFISCDI PN-IV-P7-7.1-PED-2024-0959, within PNCDI IV
6 · The paper itself

Abstract

BACKGROUND/

objectivesAccurate intraoperative tumour localisation remains challenging in minimally invasive colorectal surgery because tactile palpation is lost and conventional markers can migrate or provide imprecise localisation. Building on a preceding tri-frequency study that identified 13.56 MHz as the preferred RFID band for the intended application, this work develops a shaft-compatible NFC antenna-reader platform and evaluates its electromagnetic behaviour from bench-top reference media to five-layer tissue-equivalent phantoms.

methodsA Ø3 × 25 mm Fair-Rite Material 67 ferrite-rod antenna was designed from material and geometric parameters using finite-rod demagnetisation, inductance, resonance, and field calculations, followed by FEM cross-validation and experimental characterisation. The primary dataset comprised 480 detection distance measurements (2 media × 4 tag angles × 30 repetitions × 2 encapsulation variants). Phantom testing added 1440 measurements at 22 °C and 600 measurements at 37 °C across three fabrication batches, with the 37 °C non-coaxial subset limited to one batch.

resultsThe fabricated antenna measured 16.9 µH versus a 17.4 µH analytical estimate (-2.9%), with loaded Q = 23. The coaxial detection range was 16.45 ± 0.29 mm in air and 16.26 ± 0.21 mm in saline; angle was the dominant determinant of range (partial η

conclusionsThe study demonstrates a physics-informed route from antenna miniaturisation to measured system performance, and defines the present operating envelope under controlled bench and tissue-equivalent phantom conditions. The electromagnetic measurements apply to the antenna-electronics subassembly; integrated-shaft, multi-prototype, multi-operator, ex vivo, and in vivo validation remain necessary before clinical performance can be determined.

Indexed as

Colorectal NeoplasmsLaparoscopyPhantoms, ImagingEquipment DesignHumans13.56 MHzbiomedical instrumentationcolorectal cancerferrite antennalaparoscopic surgerymagneto-quasi-static sensingNFCphysics-informed designRFIDtumour localisation

Identifiers

PMID42817312
PMCPMC13611037

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.